ZLINE Kitchen and Bath provides Attainable Luxury, where the kitchen and bath of your dreams is never out of reach. Through our unique designs and unparalleled quality, we’re dedicated to providing you an elevated experience in the heart of your home. With an endless selection of features and finishes, our inspiration is your reality.
ZLINE is fueled by a passion for innovation; A relentless pursuit of bringing the highest end luxury designs and professional features into everyone’s homes. Because we continually strive to improve our products, we may change specifications and designs without prior notice. WARNING: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS ��������������������������������������1 BEFORE INSTALLATION ��������������������������������������������������������������4 Product Dimensions ����������������������������������������������������������������������������������������������� 4 Type Of Gas ����������������������������������������������������������������������������������������������������������� 7 Gas Pressure ��������������������������������������������������������������������������������������
IMPORTANT SAFETY INSTRUCTIONS WARNING: If the information in these WARNING instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building.
IMPORTANT SAFETY INSTRUCTIONS If the information in this manual is not followed exactly, a fire or explosion WARNING may result causing property damage, personal injury, or death. • Before beginning installation, please read and follow these important instructions for the safety of your home and the people living in it. • The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation, improper use of the appliance, or failure to heed the warnings listed.
IMPORTANT SAFETY INSTRUCTIONS An air curtain or other overhead range/range top hood, which operates WARNING by blowing downward airflow onto the range, shall not be used/installed in conjunction with this gas range top. • Please ensure that the altitude of your home is conducive for the use of gas cooking products. If the product is installed at higher altitudes above sea level, you may experience issues with gas pressure that will affect product performance.
BEFORE INSTALLATION PRODUCT DIMENSIONS 27 1/2" (699 mm) A 24" (610 mm) 36 1/8" (816 mm) 32 1/8" (816 mm) 7 7/8" (200 mm) 2 1/2" (64 mm) 2 1/8" (54 mm) B 1 1/4" (32 mm) 21 1/4" (540 mm) 2 1/2" (64 mm) 2 3/4" (70 mm) A C D E F 4" (102 mm) NOTE: The above diagram is of the RA36 model; the measurements listed without a letter Product Dimensions are universal across all RA models. See the next page for dimensions by model, and for 4 in-depth product and cutout dimensions, see pages 10–11.
BEFORE INSTALLATION PRODUCT DIMENSIONS (CONTINUED) NOTE: Product width (“A”) changes depending on size of range: • RA24 series ranges: Actual product width is 23 7/8" (606 mm) • RA30 series ranges: Actual product width is 29 3/4" (756 mm) • RA36 series ranges: Actual product width is 35 3/4" (908 mm) • RA48 series ranges Actual product width is 47 3/4" (1213 mm) • RA60 series ranges: Actual product width is 59 7/8" (1521 mm) NOTE TO INSTALLERS: Additional dimensions by letter from the previous page are outl
BEFORE INSTALLATION GAS SUPPLY • This appliance shall only be installed by an authorized professional. • If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified design, 3/4" (19 mm), is recommended for connecting this appliance to the gas supply line. DO NOT bend or damage the flexible connector when moving the appliance. • This appliance must be used with the pressure regulator provided (see below).
BEFORE INSTALLATION ROOM VENTILATION An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the appropriate national and local standards. Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the appropriate national and local standards. TYPE OF GAS This appliance is shipped from the factory for use with natural gas.
INSTALLATION INSTALLING THE LEGS The ranges must be used with the legs properly installed. Height-adjustable legs are shipped with the range in a foam container above the range. Legs are 4" (102 mm) tall and can be adjusted up to 2 1/2" (64 mm) for a maximum height of 6 1/2" (165 mm). Installing the Legs 4" (102 mm) Before installing the legs, position the appliance near its final location, as the legs are not suitable for moving the appliance over long distances. 1.
INSTALLATION INSTALLING THE ANTI-TIP SYSTEM The chains shipped with the range must be properly secured to studs on the rear wall. The height of the bracket from the floor must be determined after the range legs have been adjusted to the desired height and after the range has been leveled. WARNING A child or adult can tip the range and be fatally injured; take care to adjust the chains if the range is moved. Failure to do so can result in death or serious injury.
INSTALLATION INSTALLATION REQUIREMENTS AND CUTOUTS Installation Requirements GAS VALVE LOCATION • An agency-approved, properly-sized manual shut-off valve should be installed no higher than 3" (76 mm) above the floor and no less than 2" (51 mm) and no more than 8" (203 mm) from the right side of the range (facing product). • To connect gas between shut-off valve and regulator, use an agency-approved, properly sized flexible or rigid pipe. Check all local code requirements.
INSTALLATION Cooking Range Side View Front View W opening width 2" 5 3/4" (51 mm) (146 mm) 2 3/4" (70 mm) gas 12" (305 mm) 5" (127 mm) 36 1/8"–38 5/8" (919–981 mm) to cooking surface 3 1/4" (83 mm) location of gas and electrical extends on floor 18" (457 mm) 30"–36" (762–914 mm) to bottom of ventilation hood 6" (152 mm) 13" (330 mm) 27 1/2" (699 mm) MINIMUM CUTOUT WIDTH “W” changes with size of range: 24"–60" (610–1524 mm) RANGE SIZE EXTERNAL DIMENSIONS* 23 7/8" W x 27 1/2" D x 36 1/8" H 606
INSTALLATION ELECTRIC POWER RATING RANGE SIZE RA24 series ranges AMPERAGE 20A RA30 series ranges 15A RA36 series ranges 15A RA48 series ranges 30A RA60 series ranges 40A VAC PLUG 240 VAC NEMA 14-50P (50 AMP plug) A properly grounded and horizontally-mounted NEMA 14-50P electrical outlet should Four-Wire Connection be installed in the wall behind the range at least 2" (51 mm) above the floor and not more Receptacle than 8" (203 mm) from the bottom left side (facing product).
INSTALLATION GAS CONNECTION • All gas connections must comply with national and local codes. The gas supply line (service) must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" (13 mm) NPT inlet. Use appropriate sealant on all pipe joints that are resistant to gas. • This range can be used with natural or liquid propane gas. The range is shipped from the factory for use with natural gas.
INSTALLATION MANUAL SHUT-OFF VALVE • This valve is not shipped with the appliance and must be provided by the installer. • The valve must be installed in the gas service line between the gas hook-up on the wall and the appliance inlet, in a position where it can be reached quickly in the event of an emergency. • In Massachusetts: A T-handle type manual gas shut-off valve must be installed in the gas supply line to this appliance.
INSTALLATION PRESSURE REGULATOR Since service pressure may fluctuate with local demand, every gas cooking appliance must be equipped with a pressure regulator on the incoming service line for safe and efficient operation. Pressure Regulator • The pressure regulator shipped with the appliance has two female 1/2" (13 mm) NPT threads. • The regulator shall be installed properly in order to be accessible when the appliance is installed in its final position.
INSTALLATION LIQUID PROPANE CONVERSION PROCEDURE The gas conversion procedure for this range top includes: 1. Pressure Regulator 2. Surface Burners 3. Flame Adjustment The conversion is not finished if all steps are not completed. Before performing the gas conversion, locate the package containing the replacement orifices, which has a number indicating its flow diameter printed on the body. Consult the table below for matching orifices to burners. Save the orifices removed from the range top for future use.
INSTALLATION Gas Conversion Procedure 17
INSTALLATION Reference the diagrams below if your range was manufactured after May 2021. To check, reference the rating label under the front edge of the range. In some older models, the label may be located on the back of the unit.
INSTALLATION Gas Conversion Procedure 19
INSTALLATION STEP 1: PRESSURE REGULATOR The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with natural gas at a nominal outlet pressure of 4" W.C.P. (1 kPa) or liquid propane gas at a nominal outlet pressure of 10" W.C.P. (2.5 kPa) and it is pre-assembled from the factory to operate with one of these gas pressures as indicated in the labels affixed on the appliance, package, and instruction booklet.
INSTALLATION STEP 2: SURFACE BURNERS 1. To replace the orifices of the surface burners, lift up the burners and unscrew the orifices shipped with the range using a 7 mm socket wrench. 2. Replace orifices using the conversion set supplied with the range. Each orifice has a number indicating its flow diameter printed on the body. Consult the tables starting on page 18 for matching orifices to burners.
INSTALLATION STEP 3: FLAME ADJUSTMENT 1. Light one burner at a time and set it to the MINIMUM position (small flame). 2. Remove the knob by firmly and carefully pulling it straight out. 3. The range is equipped with a safety valve. Using the 2.0 x 50 mm flat-head screwdriver provided with this manual, locate the adjustment screw (see diagram below), hold the metal stem with one hand and turn the screwdriver to the right or left until the burner flame is adjusted to desired minimum. 4.
INSTALLATION INSTALLATION CHECKLIST 1. Is the range mounted on its legs and is the unit level? 2. Is the back guard securely connected? 3. Have the chains been properly installed? 4. Does the clearance from the side cabinets comply with the manufacturer’s direction? 5. Is the electricity properly grounded to a dedicated NEMA 14-50P receptacle? 6. Is the gas service line connected following the directions of the manufacturer? 7.
WARRANTY COVERAGE ZLINE Kitchen and Bath range products will be warrantied for one year from the original purchase date for the original purchaser of the product. This warranty covers all parts and labor for necessary repairs if any part of the product proves to be defective in materials or workmanship. The product must be deemed serviceable via troubleshooting with the ZLINE Kitchen and Bath service team.
WARRANTY WHAT IS NOT COVERED 1. Installation or start-up, damages or problems caused by improper installation or use. 2. Improper liquid propane gas conversion or damage related to improper liquid propane gas conversion. 3. Range top burner flame adjustments or related complaints. 4. Service by unauthorized service providers or damage related to unauthorized service or unauthorized parts. 5. Installation in any commercial or non-residential application. 6.
WARRANTY SERVICE For warranty service, please contact our Customer Service team at 1-614-777-5004 or visit www.zlinekitchen.com/contact to utilize our online Customer Experience Portal. Need to purchase a part or accessory for your ZLINE product? Visit www.zlineparts.com, ZLINE’s official parts distribution partner.
4.0.2 1-614-777-5004 www.zlinekitchen.com contact@zlinekitchen.