79
NOTE
The revised settings take effect after reboot. Proceed with caution.
Table 4-17 Connection setting parameters description
Name
Description
TCP
Port
Transmission Control Protocol port, the value is 37777 by default
UDP
Port
User Datagram Protocol. The default value setting is 37778. You can enter the value
according to your needs
HTTP
Port
Hyper Text Transfer Protocol port. The default setting is 80. You can enter the value
according to your actual situation, and in this case, add the modified value after the
address when logging the Device on the browser
HTTP
S Port
Hyper Text Transfer Protocol over Secure Socket Layer port. Click , and then
enter the value according to your actual situation. The default setting is 443.
RSTP
Port
Real Time Streaming Protocol port, leave it if the value is 554 by default. If you
use Apple browser QuickTime or VLC to play the real-time monitoring screen,
the following formats can be used: This function is also available for Blackberry
When the URL format requiring RTSP, you need to specify channel number and
bit stream type in the URL, and also user name and password if needed
When playing live view with Blackberry smart phone, you need to turn off the
audio, and then set the code mode to H.264B and resolution to CIF
URL format example
Rtsp://<user name>:<password>@<IP
address>:<port>/cam/realmonitor?channel=1&subtype=0
Username, such as admin
Password: For example, admin_123
IP address: For example, 192.168.1.16
Port: The default setting is 554. If the default setting is displayed, you do not
need to configure this parameter
Channel: Refers to the Channel number, starting from 1 For example, if it is
channel 2, then enter channel=2
Subtype refers to Bit stream type; 0 means main stream (Subtype=0) and 1
means sub stream (Subtype=1)
So, if you require the sub stream of channel 2 from a certain device, then the URL
should be
rtsp://admin:admin_123@192.168.1.16:554/cam/realmonitor?channel=2&subtype=
1
If certification is not required, there's no need to specify the username and
password. Use the following format
rtsp:// <IP address >: <port>/cam/realmonitor?channel=1&subtype=0
Click Apply.
4.6.2.2 Configuring 3G Settings