6” ROUND VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation – Horizontal Conversion
5HPRYHDOXPLQXPPHVK¿OWHU)URPLQVLGHWKHKRRG
disconnect blower plug located toward the right side
interior of hood body.
5HPRYHVFUHZVIURPWRSRIKRRGDQGVFUHZVIURP
back of hood attaching blower plate to hood body.
5HPRYHEORZHUDQGEORZHUSODWHIURPKRRGERG\DQG
reposition blower to hood body so blower collar protrudes
from back of hood body. Re-install blower plate to hood
ERG\XVLQJWKHVFUHZVSUHYLRXVO\UHPRYHGIURPVWHS
Re-connect blower plug.