WWW.ZEPHYRONLINE.COM Vortex AK9028BS, AK9034BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation APR21.
CORE VORTEX INSERT 2 Vortex Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
CORE Safety Information VORTEX INSERT READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. This is the Safety Alert Symbol.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information VORTEX INSERT READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions VORTEX INSERT Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round vertical or horizontal duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use calculation (on page 8) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.
CORE Installation Instructions VORTEX INSERT Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM 5-1/2” 6” 4-7/8” 2-11/16” Ů TOP (30”) 28-3/8”, (36”) 34-3/8” 10-3/8” 26-9/16” 1-1/8” (30”) 29-1/8”, (36”) 35-1/16” FRONT Vortex Use, Care, and Installation Guide 19. 8° 5/16” 17-1/2” min. 17-1/2” max.
CORE Installation Instructions VORTEX INSERT Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Hood Preparation & Installation CAUTION Recommended Side Panel Thickness: 3/4'' At least two installers are required due to the weight and size of the hood. 1. Remove baffle filter, all packing materials, and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. E C 2-1/16” cu t-o ut A D Plywood Base 2. Prepare custom cabinet enclosure by following the dimensions in FIG.
CORE Installation Instructions VORTEX INSERT Mounting the Hood 1. Lift hood into opening and install hood into cabinet. FIG D. Bottom View NOTE: Wood blocking may need to be added to cabinet base if additional support is needed. 2. Remove film from double-sided tape on the sides of front panel. FIG. E1. 3. Lift front panel up and slide into the nose of the cabinet base. The tape will temporarily hold it in place and help keep the bottom flange of the front panel flush with the hood bottom flange. FIG. E2.
Installation Instructions ZEPHYRONLINE.COM Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
CORE Features & Controls VORTEX INSERT Slide Controls 1 Blower On/OŰ III II I 2 Űħ ħ II 0 I 0 1 BLOWER ON/OFF/SPEED SELECTION ř Űĕ ĕ Ę 2 LIGHTS OFF/DIM/BRIGHT ř Űĕ ĕ Ę 16 Vortex Use, Care, and Installation Guide
Maintenance ZEPHYRONLINE.COM Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
CORE Maintenance VORTEX INSERT Installing the Filter (FIG. G): 1. Place bottom of filter into channel on hood. 2. Push filter handle in. 3. Pivot filter up and lock into place. 1 2 3 FIG. G LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. H): Push the clip 1. Remove filter. 2. Remove (4) screws from inner brackets of face place.
Wiring Diagram ZEPHYRONLINE.COM AK9028BS & AK9034BS Wiring Diagram Volts Hz Max.
CORE Troubleshooting VORTEX INSERT Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause Solutions The power source is not turned ON. The power line and the cable locking connector is not connecting properly. The blower is defective, possibly seized. The thermally protected system detects if the blower is too hot to operate and shuts the blower down. Damaged capacitor. Make sure the circuit breaker and the unit’s power is ON.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood is not venting out properly. Filter is vibrating. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size The hood might be hanging to high from the cook top. Adjust the distance between the cooktop and the bottom of the hood within 24” to 36” for gas cooktops and 20” to 36” for electric cooktops. Close all the windows and doors to eliminate the outside wind flow.
CORE List of Parts & Accessories VORTEX INSERT Description Replacement Parts LumiLight LED, 6W Baffle Filter (each) Optional Accessories Recirculating Kit Charcoal Filter Replacement Part Number Z0B0050 50210016 ZRC-9000 Z0F-C090 To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.COM y TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
CORE Product Registration VORTEX INSERT Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Vortex AK9028BS, AK9034BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation APR21.
CORE VORTEX INSÉRER 2 Vortex Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
CORE Consignes de sécurité VORTEX INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité VORTEX INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation VORTEX INSÉRER Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un conduit vertical ou horizontal rond d’au moins 6 po doit être utilisé pour maintenir une efficacité maximale du débit d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
CORE Instructions d’installation VORTEX INSÉRER Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM 5-1/2 po 4-7/8 po 6 po 2-11/16 po ¯ Ů HAUT (30 po) 28-3/8 po (36 po) 34-3/8 po 10-3/8 po 1-1/8 po 26-9/16 po (30 po) 29-1/8 po (36 po) 35-1/16 po DE FACE Vortex Guide d’utilisation, d’entretien et d’installation 5/16 17-1/2 po min. 17-1/2 po max. 20-3/8 po po 2-1/16 po po 19.
CORE Instructions d’installation VORTEX INSÉRER Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Préparation et installation de la hotte AVERTISSEMENT Épaisseur recommandée du panneau latéral : 3/4 po Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 1. Retirez le filtre déflecteur, tous les matériaux d’emballage et le film protecteur avant l’installation. Soyez prudent lors de l’installation pour éviter les rayures ou les dommages à l’acier inoxydable.
CORE Instructions d’installation VORTEX INSÉRER Montage de la hotte 1. Soulevez le capot dans l’ouverture et fixez-le. Installez le capot dans l’armoire. FIG. D. Vue de dessous REMARQUE: Des blocs de bois peuvent devoir être ajoutés à la base de l’armoire si un support supplémentaire est nécessaire. 2. Retirez le film du ruban adhésif double face sur les côtés du panneau avant. FIG. E1. 3. Soulevez le panneau avant et faites-le glisser dans le nez de la base de l’armoire.
Instructions d’installation ZEPHYRONLINE.COM Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt que comme une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et recyclé dans la maison.
CORE Fonctionnalités et commandes VORTEX INSÉRER Commandes à glissière 1 Ventilateur Marche/Arrêt / 2 Lumières Éteindre/ Veilleuse/Forte intensité Choix de Vitesse III II I 0 II I 0 1 Ventilateur Marche/Arrêt/Choix de Vitesse À 0 l’appareil est éteint; I équivaut à la vitesse lente, II à la vitesse moyenne et III à la vitesse maximale. 2 Lumières Éteindre/Forte intensité/Veilleuse À 0 la lampe est éteinte, I équivaut à la veilleuse et II à la forte intensité.
Entretien ZEPHYRONLINE.COM Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
CORE Entretien VORTEX INSÉRER Ů Ĭ Ę ĭė 1. Placez le bas du filtre dans le canal de la hotte. 2. Poussez la poignée du filtre vers l’intérieur. 3. Faites pivoter le filtre vers le haut et verrouillezle en place. 1 2 3 FIG. G LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Consultez la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées.
Schéma de câblage ZEPHYRONLINE.COM AK9028BS & AK9034BS Schéma de câblage Volts Hz Max.
CORE Dépannage VORTEX INSÉRER Problème possible Cause possible Après l'installation, l'unité ne fonctionne pas. La source d'alimentation n'est pas allumée. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement. La lumière fonctionne, Le ventilateur est défectueux, mais le ventilateur ne éventuellement grippé. tourne pas. Le système thermiquement protégé détecte si le ventilateur est trop chaud pour fonctionner et arrête le ventilateur.
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions La hotte ne s'échappe Utilisation de la mauvaise taille de Changer la gaine à la bonne taille pas correctement. conduit. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la table de cuisson et le bas de la hotte entre 24 po et 36 po pour les tables de cuisson au gaz et entre 20 po et 36 po pour les tables de cuisson électriques.
CORE Liste des pièces et accessoires VORTEX INSÉRER La description Pièces de rechange LumiLight LED, 6W Filtre déflecteur (chacun) Numéro d’article Z0B0050 50210016 Accessoires optionnels Kit de recirculation Remplacement du filtre à charbon ZRC-9000 Z0F-C090 Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
Garantie limitée ZEPHYRONLINE.COM POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
CORE Enregistrement du produit VORTEX INSÉRER Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.