WWW.ZEPHYRONLINE.COM Tornado Mini AK8400BS, AK8400BS290 EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation JAN21.
CORE TO R N A D O M I N I INSERT 2 Tornado Mini Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
CORE Safety Information TO R N A D O M I N I INSERT READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information TO R N A D O M I N I INSERT READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions TO R N A D O M I N I INSERT Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps.
CORE Installation Instructions TO R N A D O M I N I INSERT Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.
CORE Installation Instructions TO R N A D O M I N I INSERT Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood 19-3/4” At least two installers are required due to the weight and size of the hood. 10-1/4” CAUTION 1. Install optional AK084xAS Stainless Steel Liner. Review manual included with liner for more details. cabinet bottom cut-out size FIG. B 2. If no liner is used, cut out an opening in bottom of the cabinet by following the dimensions in FIG. B. Front View 3. Remove aluminum mesh filter. 4.
CORE Installation Instructions TO R N A D O M I N I INSERT Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
Features & Controls ZEPHYRONLINE.
CORE Maintenance TO R N A D O M I N I INSERT Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Maintenance ZEPHYRONLINE.COM Installing Aluminum Mesh Filters (FIG. G): 1. Place back of filter into channel on left side of Power Pack. 2. Pull filter handle towards left side of Power Pack. 3. Pivot filter up and lock into place. 1 2 3 FIG. G Replacing Aluminum Mesh Filters Hood Model AK8400BS AK8400BS290 Part Number 50200054 50200054 Qty. to Order 1 1 To order parts, visit us online at http://store.zephyronline.com.
CORE Wiring Diagram TO R N A D O M I N I INSERT WIRING DIAGRAM B/W B/W B/W BLACK RED BROWN RED MOTOR YELLOW WHITE BODY GREEN WHITE BLUE BLACK GREY ė śŞ ų Śśř şř ĕ Ŝ ų śŢř 18 Tornado Mini Use, Care, and Installation Guide
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. The unit is vibrating. Possible Cause Solutions The power source is not turned ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. Make sure the circuit breaker and the unit’s power is ON. Check the power connection with the unit is connected properly.
CORE Troubleshooting TO R N A D O M I N I INSERT Possible Problem The hood is not venting out properly. Filter is vibrating. 20 Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 20” (electric cook tops) or 24” (gas cook tops) and 36” range. Close all the windows and doors to eliminate the outside wind flow.
List of Parts & Accessories ZEPHYRONLINE.COM Description Replacement Parts LumiLight LED, 6W Aluminum Mesh Filter Optional Accessories Recirculating Kit Replacement Charcoal Filter Liner, 30” Liner, 36” Part Number Z0B0049 50200054 ZRC-8400A Z0F-C084 AK0840AS AK0846AS To order parts, visit us online at http://store.zephyronline.com.
CORE Notes TO R N A D O M I N I INSERT 22 Tornado Mini Use, Care, and Installation Guide
Limited Warranty ZEPHYRONLINE.
CORE Product Registration TO R N A D O M I N I INSERT Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Tornado Mini AK8400BS, AK8400BS290 EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation JAN21.
CORE TO R N A D O M I N I INSÉRER 2 Tornado Mini Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
CORE Consignes de sécurité TO R N A D O M I N I INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité TO R N A D O M I N I INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation TO R N A D O M I N I INSÉRER Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un conduit d’au moins 6 po rond ou 3-1/4 po x 10 po rectangulaire doit être utilisé pour maintenir une efficacité maximale du flux d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
CORE Instructions d’installation TO R N A D O M I N I INSÉRER Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.
CORE Instructions d’installation TO R N A D O M I N I INSÉRER Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte ATTENTION 1. Installez une doublure en acier inoxydable AK084xAS en option. Consultez le manuel inclus avec la doublure pour plus de détails. L/C 10-1/4 Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 19-3/4 L/C ¯ £ Ġ FIG. B 2. Si aucune doublure n’est utilisée, découpez une ouverture au bas de l’armoire en suivant les dimensions de la FIG. B.
CORE Instructions d’installation TO R N A D O M I N I INSÉRER Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt que comme une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et remis en circulation dans la maison.
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes à glissière 1 Ventilateur Marche/Arrêt / III II I 2 Lumières Éteindre/ Veilleuse/Forte intensité Choix de Vitesse 0 II I 0 1 Ventilateur Marche/Arrêt/Choix de Vitesse À 0 l’appareil est éteint; I équivaut à la vitesse lente, II à la vitesse moyenne et III à la vitesse maximale. 2 Lumières Éteindre/Forte intensité/Veilleuse À 0 la lampe est éteinte, I équivaut à la veilleuse et II à la forte intensité.
CORE Entretien TO R N A D O M I N I INSÉRER Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
Entretien ZEPHYRONLINE.COM Ů £ Ĭ Ę ĭė 1. Placez l’arrière du filtre dans le canal sur le côté gauche du bloc d’alimentation. 2. Tirez la poignée du filtre vers le côté gauche du bloc d’alimentation. 3. Faites pivoter le filtre vers le haut et verrouillez-le en place. 1 2 3 FIG.
CORE Schéma de câblage TO R N A D O M I N I INSÉRER 0 N/B N/B N/B NOIR ROUGE GRIS MOTEUR JAUNE BLANC CORPS VERT BLANC BLEU ROUGE NOIR MARRON ė śŞ ų Śśř şř ĕ Ŝ ų śŢř 18 Tornado Mini Guide d’utilisation, d’entretien et d’installation
Dépannage ZEPHYRONLINE.COM Problème possible Après l'installation, l'appareil ne fonctionne pas. Cause possible Solutions La source d'alimentation n'est pas allumée. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement. Les câblages du tableau de commande ou du tableau de commande sont déconnectés. Assurez-vous que le disjoncteur et l’appareil sont sous tension. Vérifiez que la connexion électrique avec l'appareil est correctement connectée.
CORE Dépannage TO R N A D O M I N I INSÉRER Problème possible Cause possible Solutions Les LED LumiLight N/A Il s’agit d’une opération normale et la clignotent lors du hotte fonctionne correctement. changement de niveau de vitesse. La hotte ne s'échappe Utilisation de la mauvaise taille de Changer le conduit à la bonne taille. pas correctement. conduit. La hotte est peut-être suspendue trop haut de la table de cuisson.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange LumiLight LED, 6 W Filtre à mailles en aluminium Numéro d’article Z0B0049 50200054 Accessoires optionnels Kit de recirculation Filtre à charbon de rechange Doublure, 30 po Doublure, 36 po ZRC-8400A Z0F-C084 AK0840AS AK0846AS Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
CORE Remarques TO R N A D O M I N I INSÉRER 22 Tornado Mini Guide d’utilisation, d’entretien et d’installation
Garantie limitée ZEPHYRONLINE.
CORE Enregistrement du produit TO R N A D O M I N I INSÉRER Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.