Installation Guide

14
www.zephyronline.com
1. Power / Delay Off
Power Button Function
On/Off button will turn power on and off for entire hood (fan and lights). The hood will remember the last speed and light level it
was turned off at.
Delay Off Button Function
With the fan on, press and hold the On/Off button for three seconds. The fan will change to speed 1 and the 10 minute delay off
timer will start. A countdown timer will show on the display indicating the time left until the fan and lights automatically turn off.
Pressing the On/Off button while the Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function.
ACT Verification
Airflow Control Technology (ACT™) allows the installer to set the maximum blower CFM to align with local codes and regulations.
To verify the maximum blower CFM:
With hood off, hold the On/Off button for three seconds. The Display will show if ACT™ is disabled and set to the maximum
CFM or if ACT™ is enabled and set to one of the restricted maximum CFM levels of 590, 390 or 290.
2. Speed Selection
The 6 speed levels are selected by pressing Fan - to decrease and Fan + to increase speed levels. The Display indicates the
speed level selected.
ACT Enabled Speed Selections
When ACT™ is enabled, the number of fan speeds will be reduced to Maximum 3 speeds.
3. Lights On/Dim/Off
Switch lights on by pressing Lights button once, press a second time to dim and again to shut off lights.
4. Display
The display window indicates speed levels and features such as baffle filter clean reminder, delay off and clean air indicator.
Filter Clean Reminder
After 30 hours of fan usage the words “Clean grease filters” will show on the Display indicating it is time to clean the filters.
To Reset: With hood off, hold the Fan - button for 3 seconds until the display words “Clean grease filters” turns off
Clean Air
Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.
To enable Clean Air Function:
With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAir Function
Activated” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan will turn off and the 4 hour
timer will begin.
To disable Clean Air Function:
With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAIr Function
Deactivated” will illuminate indicating the function has been disabled.
When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10
minutes the fan will turn off and the 4 hour timer will reset.
If the user changes the fan speed while the Clean Air Function is in use, the Clean Air Function will stop. If the user presses the
On/Off button at any time the 4 hour Clean Air timer will reset.
Optional Remote Control Pairing
To create a unique link between your hood and optional remote control please follow these steps.
With Hood off, press and hold the Lights button until the Display shows the words “Remote Pairing...” then press any button on
the remote, the Display will then show the words “Remote Paired” indicating the remote control pairing is complete.
Power / Delay Off
Adjust 6 Speed Levels
Display
Lights On/Dim/Off
Features & Controls – Electronic LCD Controls