Use, Care, and Installation Guide www.zephyronline.com Breeze I AK1124x, AK1100x, AK1136x Breeze II AK1200Bx, AK1236Bx Breeze I Model number: Serial Number: Date of Purchase: Sales Dealer: JUN17.0201 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... 6SHFL¿FDWLRQV ............................................................... Preparing Electrical .................................................... Preparing Electrical and Ducting .......................... Converting to Air Recirculating Mode ................. Mounting the Range Hood ......
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. For indoor use only. Do not use over cooking equipment greater than 60,000 BTU/hr. This hood is not intended to be used as a shelf. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJ
List of Materials www.zephyronline.com MODELS: BREEZE I - AK1124x, AK1100x, AK1136x BREEZE II - AK1200Bx, AK1236Bx PARTS SUPPLIED 1 - Hood $OXPLQXP PHVK ¿OWHUV 2 - Halogen light bulbs, GU-10 35W, Breeze I Only 1 - LED Light Strip, 5W, Breeze II Only ´ [ ´ UHFWDQJXODU VWDUWLQJ FROODU ZLWK GDPSHU ORFDWHG LQVLGH KRRG ERG\ 1 - Hardware package HARDWARE PACKAGE CONTENTS M4 x 2” (4) M4 x 1-1/2” (4) M4 x 1” (4) M4 x 8 (10) Wood screw washers (4) Wire Caps (3) PARTS NOT SUPPLIED - Ducting, co
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 24”. Maximum mount height should be no higher than 32”. It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG ¿UH KD]DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORVH LWV SHUIRUPDQFH DQG HI¿FLHQF\ in. ” m x.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only.
Installation – 6SHFL¿FDWLRQV www.zephyronline.com TOP 35-15/16” (36”) 29-15/16” (30”) 23-15/16” (24”) 2-3/4” 1/2” 10” C/L 12-3/16” 8-5/8” 3-1/4” 9-1/16” 10-7/8” elec. k/o 2” 1-3/8” 33-7/8” (36”) 27-7/8” (30”) 22-1/16” (24”) Air Recirculating Louver Plate 33-5/8” (36”) 27-5/8” (30”) 21-5/8” (24”) 5-1/2” elec.
WARNING $OO (OHFWULFDO ZRUN PXVW E\ SHUIRUPHG E\ TXDOL¿HG HOHFWULFLDQ RU SHUVRQ ZLWK VLPLODU WHFKQLFDO NQRZ how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Preparing Electrical and Ducting www.zephyronline.com 1. Remove filters 2. Remove cover from junction box to gain access to electrical wiring. 3. If using a cable lock, pry open the desired electrical knockout either on top or back of hood. Feed the wires through the cable lock. Some local codes require the use of a cable lock, check your local codes. 4. If using hood in air recirculating mode skip steps 4 and 5. 5.
NOTE: Skip the recirculating preparation pages if you are ducting the air out of your home. 1. Secure each of the (2) spring clips to the safety grille body (A). Do this by inserting the screw through the spring and into the clip. Secure each clip to the safety grille body by using a philips head screwdriver. An air recirculating kit (optional) must be purchased before using hood in recirculating mode. Recirculating kit - 0AK11-21001 5HSODFHPHQW ¿OWHU $. 2.
Installation – Converting to Air Recirculating Mode www.zephyronline.com NOTE: Skip this page if you are ducting the air out of your home. 5. Remove each of the 5 screws holding the (2) interior recirculating panels. 7. Place louvered recirculating plate over top opening and secure using the screws previously removed. 12 6. Remove (2) interior recirculating panels.
Hood is designed for installation under a kitchen cabinet (Fig 1) Duct opening cutout 6HOHFW SUHIHUUHG GXFW ORFDWLRQ YHUWLFDO RU KRUL]RQWDO LI ducting out of kitchen. Refer to page 7 for details. %HJLQ LQVWDOODWLRQ E\ UHPRYLQJ WKH ¿OWHUV LI LQVWDOOHG DQG VLGH VSDFHU SDQHOV ´ PRGHOV RQO\ )LJ duct/silver tape 3. Reinforce cabinet with 1”x2” wood strips if additional strengthening is required or if cabinets are framed. 4.
Features & Controls – Controls & Features www.zephyronline.com Breeze I, AK11xx Blower On/Off/Speed Selection Lights Off/Dim/Bright This switch turns the blower on and off and controls the speed selection. is off, is low speed, is medium speed and is high speed. Lights Off/Dim/Bright is off, is dim, II is bright. Breeze II, AK12xxBx This button turns the motors on and off. It also shuts off power to the whole hood. If the lights are on and this button is pushed, they will also turn off.
Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel &OHDQ SHULRGLFDOO\ ZLWK ZDUP VRDS\ ZDWHU DQG FOHDQ FRWWRQ FORWK RU PLFUR ¿EHU FORWK $OZD\V UXE LQ WKH direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Maintenance – Lights www.zephyronline.com BREEZE I, AK11xx model ONLY REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. ,I EXOEV DUH GLI¿FXOW WR WXUQ GXH WR SURORQJHG XVH ¿UPO\ DWWDFK D JODVV VXFWLRQ FXS DSSUR[LPDW
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch or control board wirings are disconnected. 3. Make sure the wirings at the switch or control board are connected properly. 4. The wires on control board or switch are loose. 4.
Models: AK1200Bx, AK1236Bx Voltage: 120V 60Hz Power consumption Total: 70W @0.8A Lamp: 5W Fan: 65W THERMALLY PROTECTED 18 RED BLACK Wiring Diagrams www.zephyronline.
PART # Replacement Parts /LJKW %XOE 05 *8 : HDFK $. [[ 2QO\ = % 0HWDO )LOWHU ´ KRRGV HDFK 0HWDO )LOWHU ´ DQG ´ KRRGV HDFK Optional Accessories Recirculating Kit 5HSODFHPHQW &KDUFRDO )LOWHUV SN 0AK11-21001 $. To order parts, visit us online at http://store.
Warranty www.zephyronline.
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | 21 Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Breeze I AK1124x, AK1100x, AK1136x Breeze II AK1200Bx, AK1236Bx Breeze I Numéro de modèle : Numéro de série : Date d’achat : Détaillant : JUN17.0201 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit ........................... Espace libre et hauteur de montage ................... Options d’installation pour le conduit .................. 6SpFL¿FDWLRQV ............................................................... Préparation de l’électricité .............................. Préparation de l’électricité et du conduit ........ Conversion en mode de reprise d’air ............. Montage de la hotte .......................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage. Pour utilisation à l’intérieur seulement Ne pas utiliser sur d’équipement de cuisson qui est supérieure à 60 000 BTU/h.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com La hauteur de montage minimale entre la hotte et la FXLVLQLqUH QH GHYUDLW SDV rWUH PRLQV GH ´ La hauteur de montage maximale ne devrait pas H[FpGHU ´ Il est important d’installer la hotte à la hauteur de montage adéquate.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
Installation – 6SpFL¿FDWLRQV www.zephyronline.
AVERTISSEMENT 7RXV OHV WUDYDX[ pOHFWULTXHV GRLYHQW rWUH UpDOLVpV SDU XQ pOHFWULFLHQ TXDOL¿p RX SDU XQH SHUVRQQH SRVVpGDQW l’expérience technique et le savoir-faire nécessaire. Pour votre sécurité, enlevez le fusible ou ouvrez le disjoncteur de circuit avant de commencer l’installation. 1¶XWLOLVH] SDV GH FRUGRQ SURORQJDWHXU RX GH ¿FKH G¶DGDSWDWLRQ DYHF FHW DSSDUHLO Suivez les codes et réglementations nationaux ou locaux en vigueur.
Installation – Préparation de l’électricité et du conduit www.zephyronline.com 1. Retirez les filtres. 2. Retirez le couvercle de la boîte de jonction pour avoir accès au câblage électrique. 3. Si vous utilisez un raccord de câble, ouvrez soit l’une des entrées défonçables pour l’électricité (sur le dessus ou à l’arrière de la hotte). Faites passer les fils électriques par le raccord de câble.
NOTE : Sautez les pages de conversion en mode de reprise d'air si vous évacuez l'air à l'extérieur de votre maison. Vous devez vous procurer un ensemble de reprise d’air (non inclus) avant d’utiliser la hotte en mode de reprise d’air. Ensemble de reprise d’air – 0AK11-21001 Filtre de rechange – 0AK11-20001 2. Installez le filtre à charbon dans le support de filtre à charbon (B) et placez-le sur le boîtier de la grille de protection (A). 1.
Installation – Conversion en mode de reprise d’air www.zephyronline.com NOTE : Sautez cette page si l’air évacué par la hotte est dirigé à l’extérieur de votre maison. 5. Enlevez les cinq vis qui retiennent les deux panneaux de reprise d’air intérieurs. 7. Placez les deux déflecteurs de reprise d’air sur l’ouverture supérieure et fixez-les en place à l’aide des vis préalablement enlevées. 12 6. Enlevez les deux panneaux de reprise d’air intérieurs.
fil électrique 1. Choisissez le type d’installation pour le conduit (vertical ou horizontal) découpage de l’ouverture pour le conduit &RPPHQFH] O¶LQVWDOODWLRQ HQ HQOHYDQW OHV ¿OWUHV V¶LOV VRQW déjà en place) et les panneaux lateraux d’ecartement ´ PRGHOHV XQLTXHPHQW )LJ 3. Renforcez la base de l’armoire avec des lattes de bois de ´ ; ´ VL XQ UHQIRUFHPHQW VXSSOpPHQWDLUH HVW QpFHVVDLUH ou si les armoires sont en bois. ruban adhésif en toile/réflecteur 4.
Commandes – Survol des commandes www.zephyronline.com Breeze I, AK11xx Ventilateur Marche/Arrêt /Choix de Vitesse Lumières Allumer/ Éteindre/Veilleuse Ventilateur - Marche / Arrêt / Choix de Vitesse Cet interrupteur permet d’allumer, d’éteindre et de sélectionner la vitesse des ventilateurs. À 0 l’appareil est éteint; I équivaut à la vitesse lente, II à la vitesse moyenne et III à la vitesse maximale.
N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de produits de nettoyage pour le four. N’utilisez aucun produit contenant de l’eau de Javel ou un produit contenant du chlorure. N’utilisez pas de laine d’acier ou des plaques abrasives qui risqueraient d’égrativer et d’endommager la surface. Nettoyage en acier inoxydable Nettoyez périodiquement avec de l’eau chaude savonneuse et nettoyez un chiffon en coton ou un chiffon PLFUR¿EUH 7RXMRXUV IURWWHU GDQV OH VHQV GX JUDLQ HQ DFLHU LQR[\GDEOH
Entretien – Lumières www.zephyronline.com AK11xx, Breeze I seulement REMPLACEMENT DES AMPOULES ATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées. Veuillez NE PAS les toucher avant de les avoir éteintes et laissées refroidir. Le contact avec les ampoules chaudes pourrait causer de sérieuses brûlures. Assurez-vous que l’alimentation électrique est coupée et que les ampoules ne sont pas chaudes.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que le disjoncteur et que l’alimentation de l’appareil sont allumés. 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés. 9pUL¿H] TXH OH EUDQFKHPHQW GH O¶DSSDUHLO D pWp fait correctement. /HV ¿OV pOHFWULTXHV GX WDEOHDX GH FRQWU{OH HW GH commande sont débranchés.
RED BLACK Schema De Cablage www.zephyronline.com SCHEMA DE CIRCUITS BLANC BLANC BLANC Consummation d’endergie 70W @0.
Nº DE PIÈCE Pièces de rechange : Ampoule GU10 35W (chaque) (Breeze I) Z0B0023 )LOWUH HQ PpWDO KRWWH GH ´ FKDTXH )LOWUH HQ PpWDO KRWWH GH ´ HW ´ FKDTXH Accessoires facultatifs : Ensemble de reprise d’air Filtre à charbon de rechange (chaque) 0AK11-21001 0AK11-21001 Pour commander des pièces, visitez-nous en ligne au http://store.zephyronline.com ou communiquez avec nous par téléphone au 1.888.880.
www.zephyronline.
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits.