Data Sheet
M5S analogue input - „AI“
• For measurement of analogue signals,
potentiometers, temperature sensors as well as
other current or voltage sources
• Optional: isolated or non-isolated signal
• Multi function: DC Voltage/current as well as
different types of temperature sensors
M5S-AIV03010A3, M5S-AIV05010A3
Description Internal circuit External circuit
Version Signal Supply Isolation Signal Supply
Analogue input
voltage non-isolated
AIV03 0-2.5 V DC 3.3 V/10 mA DC No 0-10 V DC
common ground
18-30 V
10 mA DC
AIV05 0-3.3 V DC 5 V/10 mA DC
M5S-AIV03010-A3
EXT+
INT-S
EXT-S
EXT-
INT-
U
U
EXT
18-30 V
0 V 10 V
- +
V
0 V 2.5 V
U
+ -
U
INT
3.3 V
INT+
1
2 3 4
5
6
7
8
M5S-AIV05010-A3
EXT+
INT-S
EXT-S
EXT-
INT-
U
U
EXT
18-30 V
0 V 10 V
- +
V
0 V 3.3 V
U
+ -
U
INT
5 V
INT+
1
2 3 4
5
6
7
8
M5S-AIV03010B3, M5S-AIV05010B3
Description Internal circuit External circuit
Version Signal Supply Isolation Signal Supply
Analogue input
voltage isolated
AIV03 0-2.5 V DC 3.3 V/10 mA DC Yes 0-10 V DC 18-30 V
10 mA DC
AIV05 0-3.3 V DC 5 V/10 mA DC
EXT+
INT-S
EXT-S
EXT-
INT-
V
U U
+ -
U
INT
3.3 V
U
EXT
18-30 V
0 V 2.5 V
- +
M5S-AIV03010-B3
INT+
1
2 3 4
5
6
7
8
0 V 10 V
EXT+
INT-S
EXT-S
EXT-
INT-
V
U U
+ -
U
INT
5 V
U
EXT
18-30 V
0 V 3.3 V
- +
M5S-AIV05010-B3
INT+
1
2 3 4
5
6
7
8
0 V 10 V
Page 4 of 10 www.tde-instruments.de