ZANUSSI Hobs OPERATING AND INSTALLATION MANUAL 2
CONTENTS Technical characteristics General warnings Instructions for user Use Maintenance and cleaning Instructions for installer Gas connection Electrical connection Adaption of hob burners to different types of gas Insertion in kitchen units Technical assistance and spareparts Pag. Pag. Pag. Pag. Pag. Pag. Pag. Pag. Pag. Pag. Pag.
WARNINGS - GAS HOBS It is most important that this instruction brochure should be kept together with the appliance for future consultation. If the appliance is sold or transferred to another person, ascertain that the brochure is also given, in order that the new user can be aware of the correct use of the machine and the relative warnings. THESE WARNINGS HAVE BEEN PREPARED FOR YOUR SAFETY AND FOR THAT OF OTHERS, WE THEREFORE REQUEST YOU TO READ THEM CAREFULLY BEFORE INSTALLING AND USING THE APPLIANCE.
INSTRUCTIONS FOR THE USER 3 2 1 6 7 4 8 9 5 1. 2. 3. 4. 5. 6. 7. 8. 9.
INSTRUCTIONS FOR USER INSTALLATION All operations relating to installation, regulation and adaption to the type of gas supplied, must be carried out by qualified personnel, according to the regulations in force. Specific instructions are contained in the notices reserved for the installer. USE Hob control switch The switches for the gas burners of the hob are situated on the control panel.
MAINTENANCE AND CLEANING Before each operation electrically disconnect the appliance. Wash the enamelled parts with warm water and detergent, do not use abrasive products which could damage them; frequently wash the baffles of the burners with boiling water and detergent, taking care to remove all encrustrations; the parts in stainless steel should be rinsed well with water after use and dried with a soft cloth. The hob’s enamelled grills can also be washed in the dishwasher.
CONNECTION TO THE GAS SUPPLY CONNECTION Gas connection must be carried out in conformity with the regulations in force. The appliance leaves the factory tested and regulated for the type of gas indicated on the plate which is situated in the lower position near the gas connection tube. Ascertain that the type of gas with which the appliance will be supplied is the same as that indicated on the plate.
ELECTRICAL CONNECTION The appliance is predisposed to function with a 230V monophase voltage tension. Connection must be carried out in conformity with the regulations and dispositions of the laws in force. Before connecting ensure that: - The limiter valve and the electrical mains can support the voltage of the appliance (see registration plate). - The power supply is correctly earthed according to the regulations in force.
ADAPTATION TO DIFFERENT TYPES OF GAS SUBSTITUTION OF THE NOZZLES Remove the grills: Remove the caps and baffles from the burners: With a tubular spanner no. 7 unscrew and remove (fig. 5) the nozzles substituting them with those corresponding to the type of gas used (see tab): Remount the parts carrying out the operations described in reverse. Then substitute the caliber plate (positioned near the gas supply connection) with the one corresponding to the new type of gas.
a) minimum regulation screw b) normal tap FO 1045 c) valvular tap Fig. 8 Fig. 9 TYPE OF GAS NATURAL GAS (methane) L.P.G.
INSTALLATION IN THE KITCHEN UNITS DIMENSIONS CUT OUT DIMENSIONS Height (overall): Depth: Width: Thickness: Automatic Taps Ignition Switches: Gas Hob Burners: Height: Depth: Width: Weight: 74 mm. (see drawing) 510 mm. 580 mm. 30 mm. 72 mm. 480 mm. 560 mm. 9 Kg. 30 12 YES 1 Rapid Burner (front left) 1 Auxiliary Burner (front right) 2 Semirapid Burners (back) 0 74 554 0 13 16,5 13 58 51 SR 477 510 SR A 0 48 580 56 0 16,5 R FO 0767 Fig. 10 FO 0697 Fig.
INSERTION AND ASSEMBLY POSSIBILITY FOR INSERTION The hobs can be installed in a unit having an opening for installation of the dimensions illustrated in fig. 11. The fixture of the hob to the unit must be carried out as follows: position the appropriate sealings, supplied, on the edge of the opening predisposed taking care that the edges meet without overlapping; place the hob in the opening of the unit taking care in centring; fix the hob to the unit by means of the appropriate clips (see fig. 12).
Kitchen unit with oven The opening should have the dimensions shown in figs. 13-14 and be provided with supports to permit an efficient ventilation. To avoid excessive overheating it is advisable to carry out installation as (figs. 16-17). The electrical connection of the hob and that of the oven must be carried out separately, both for electrical reasons and to facilitate the frontal extraction of the oven. 50 cm 2 120 cm 2 180 cm 2 FO 0939 360 cm 2 Fig. 16 FO 0938 Fig.
TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory this appliance was tested and controlled by expert and specialized personnel in order to give the best working results. All repairs or controls which may be necessary should be undertaken with maximum care and attention. For this reason we recommend you always contact the Retailer who sold it or our nearest Assistance Centre, specifying the type of problem and the model of the appliance in your possession.