Commercial Dehumidifier Please read the manual carefully before using the unit DP600C USER MANUAL , www pulley com
MCGUFFEY FOR CUSTOMERS Thank you for purchasing our dehumidifier. McGuffey wishes our products and services can bring convenience to your work and life. We highly recommend you to keep the manual for reference, in case you encounter unexpected issues using this unit. Please read the manual carefully to ensure proper use of the dehumidifier. Our dehumidifiers are widely used in family bedrooms, bathrooms, basements, offices and storage rooms, etc.
BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.
MCGUFFEY CATALOG Safely HUTCHINSON iia linen nemesis n serene 1 Parts PRESCHOOL. cocoons serer smerememeserereseressenenenenereres 02 Operation Desertions co... homeroom ooo ooo 03 Status Adsorptions. coercive vistas sss ve assassinates 08 Drainage Description... Care & Cleaning. mor mms si 10 Common Faults & ome moomoaemmeeomondd 1 Safety Notes... CANOEING. cet tenner Anne rte 13 Warranty & Contact Us...
SAFETY INSTRUCTIONS For your safety, please read and keep the manual properly before or after using the unit. Please use the product In accordance with the Instructions In this manual. Unplug the dehumidifier from the power source when cleaning. De not splash water into the machine or put it near places where it can be splashed. Please do not place the machine near a heating device or dangerous inflammable things. Do not put your fingers or any hard materials into the air inlet or outlet.
PARTS DESCRIPTION Control Pans Handle Air Outlet Alp Inlet Hard Button {Tu access the water tank) Caster Continuous Drainage Port Cable Gut lat
OPERATION DESCRIPTIONS 2. Setting Power ‘When the unit is ON, press [POWER] fo enable Standby mode. Then the unit stops working and the standby indicator ¢ tums on. When the unit is OFF, press [DOWER] to tum on the unit. Then the unit starts working and the standby indicator ¢ tums off. Humidity Setting When the unit is ON, press [Up] or [Down] to enter the humidity setting. The humidity display %RH flashes and humidity "BB" flashes to show the level.
OPERATION DESCRIPTIONS Cleaning Setting = Cleaning Time Setting When the unit is on, hold the button [Cleaning] to enter cleaning setting. The icon Cleaning lights up, and the number "BB" displays the cleaning days. Press the button once again or wait for seconds to exit the setting. In tha cleaning setting, press [Up] or [Down] to adjust the cleaning time between 01-99 days. (cyclones setting). Press [Up] once to increase 1 day while decreasing 1 day by pressing [Down] once.
STATUS DESCRIPTIONS 1. Unit Working Description The compressor and fan will stop working successively when tum off the dehumidifier. The compressor will stop working immediately, and the fan stops working later, whenever the Protection is triggered, the humidity level set before is reached, or breakdown occurs. Compressor 3 Minutes Delay Protection: After the unit has stopped, it can not be restarted in the first 3 minutes to protect compressor operation. The unit will restart automatically after 3 minutes.
STATUS DESCRIPTIONS 3. Protectionist Code ERE Change the sensor and connecting cable of the R HI-112A port, 2 E2 Change the temperature sensor of PTI port. 3 © Make sure the water tank is well placed, and the WF port is properly connected. 4 E4 Change the sensor and connecting cable of the R HI-112A port. s 6 Make sure the display circuit has been connected right, and the DISPLAY port is well connected. No problem. The unit resumes working when unit temperature goes 6 ~H down. 7 -L No problem.
DRAINAGE DESCRIPTION 1. Drainage Description Two ways are available to remove the collected water. ‘Water Tank Drainage When the full tank indicator flashes, press the two locks at front side simultaneously (see picture 1) to open the panel. Then refer to picture 2 to remove the bucket and empty the water. Put the water tank back inch place and fix the cover when emptying the bucket. ‘Ways to Empty the Water Tank a ww 0 Put the water tank back In place, and close the Empty the water tank.
DRAINAGE DESCRIPTION 2. Continuous Drainage For continuous draining, you need to press the two locks at front side simultaneously (see picture 1} to open the panel. Then refer to pictures 3 to connect a drain hose (inner diameter 16mm) to drain the water. Note: 1. Fix the hose into the groove to avoid fall-off, and cause water leakage. 2. The water tank must be placed Inside the unit for using the continuous drainage, or the unit may fall to work.
CARE & CLEANING Ah WARNING: Tum the dehumidifier off and remove the plug from the wall outlet before cleaning. A. Housing Washing Do not use volatile chemicals, gasoline, detergent, or other related detergents to clean the exterior, for that may damage the coating to accurate the corrosion. B. Filter Cleaning It's advised to clean the filter regularly and properly. Make sure clean the filter at least once a month.
COMMON FAULTS & SOLUTIONS Check the information below for troubleshooting steps, it will save you time to resolve issues that may happen with the unit. The list Includes most of the common cases, but not the results of defective unt, crafts or materials In the unit. If all troubleshooting steps have been exhausted and the issue is still occurring, please feel free to reach out to McGuffey Customer Service to get further assistance.
SAFETY NOTES When using, please donuts {3 Do not insert thin rods and hard &3 When using, please keep the the machine at the soft and objects Into the machine body to machine away from heating uneven ground, avoid vibration avoid malfunction and danger. furnaces, electric kettle and and movement. other heat sources. 3 When using, plazas close doors {3} Please do not put objects around {311 do not use the product fora and windows to achieve the best the body.
SPECIFICATIONS MODEL DP&00C POWER SOURCE 115V~60Hz TOTAL INPUT CURRENT 798 MOISTURE REMOVAL 48.5 Pints/Day (23L/Day) MOISTURE REMOVAL 74 Pints/Day (36L/Day) MOISTURE REMOVAL 123 Pints/Day (58L/Day) MOISTURE REMOVAL 155 Interplay (73L/Day) INPUT POWER 500W INPUT CURRENT 54A IEF 1.92 liters Wh MOTOR FLA 0.76A MOTOR COMPRESSOR (RLA/LRA) LRA:30A REFRIGERANT R410a/450g MAXIMUM ALLOWABLE PRESSURE 5.5MPa (800 PSI) HIGH PRESSURE 4.0MPa (580 PSI) LOW PRESSURE 1.
WARRANTY & CONTACT US Warranty McGuffey offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occurs, including those newly purchased and unused, from McGuffey or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.