Garden Arbor - Faux Glass Installation and Operating Instructions – YM11629 Revised 01/28/2013 Yardistry – North America Toll Free Customer Support: 1.888.509.4382 info@yardistrystructures.com www.yardistrystructures.com Yardistry / Selwood Products – Europe Customer Support: +44 1284 852569 parts@selwoodproducts.com www.selwoodproducts.com 1 support@yardistrystructures.
Important Safety Notice! Yardistry components are intended for privacy, decorative and ornamental use only. Product is NOT INTENDED for the following: • A safety barrier to prevent unsupervised access to pools, hot tubs, spas or ponds. • As load bearing support for a building, structure, heavy objects or swings. • Used in structures that trap wind, rain or snow that would create extra load on the product. Permanent structures may require a building permit.
Limited Warranty Yardistry warrants that this product is free from defect in materials and workmanship for a period of one year from the original date of purchase. In addition, all lumber is warranted for 5 years against rot and decay. This warranty applies to the original owner and registrant and is non-transferable. Regular maintenance is required to assure the integrity of your product and is a requirement of the warranty. This warranty does not cover any inspection cost.
are approximate and are shown to assist in the identification of parts for Part Identification ( Dimensions ) assembly. Actual dimensions may be smaller or larger. 4pc. (208) - Arbor Ends 25.4 x 114.3 x 254mm 2pc. (204) - Arbor Side 25.4 x 114.3 x 582.1mm 2pc. (200) - Arbor Arch Beam 25.4 x 292.1 x 1746.3mm 5pc. (203) - Arbor Trellis 25.4 x 76.2 x 1041.4mm 4pc. (209) - Cross Brace 38.1 x 76.2 x 496.3mm 4pc. (206) - Engineered Panel Post 50.8 x 76.2 x 2286mm 2pc. (316) - 3 High Faux Glass Panel 38.
Hardware Identification ( Dimensions are approximate and are shown to assist in the identification of parts for assembly. Actual dimensions may be smaller or larger. ) 32pc. - Wood Screw #8 x 3" - (Y06416-530) 10pc. - Wood Screw #10 x 4" - (Y06416-940) 16pc. -1/4" Flat Washer (Y05416-201) 12pc. - Hex Bolt 1/4 x 2-3/4" - (Y07416-223) 4pc. - Hex Bolt 1/4 x 4" - (Y07416-249) 16pc. -1/4" Lock Washer (Y05416-204) 16pc. - Tee Nut 1/4" - (Y08416-206) 1pc.
Inventory Parts - Read This Before Starting Assembly STOP A. STOP STOP STOP his is the time for you to inventory all your hardware, wood and accessories, T referencing the parts identification sheets. This will assist you with your assembly. •E ach step indicates which bolts and/or screws you will need for assembly, as well as any flat washers, lock washers, t-nuts or lock nuts. B.
Step 1: Assemble Panels A: Lay both (206) Engineered Panel Posts on edge so the grooved sides face each other, on a level surface. B: Place one (209) Cross Brace in between the posts tight to the top of the ledge of the (206) Engineered Panel Posts and attach with two (YS4) #8 x 3” Wood Screws per side as shown in fig. 1.1. Repeat for a second assembly. Note hole orientation. Fig. 1.1 206 Flush to top of post ledge on both sides. 4x 2x 206 209 209 YS4 Wood Parts Engineered Panel Post 50.8 x 76.
Step 2: Assemble Panels A: Insert into the grooves of both (206) Engineered Panel Posts, one (316) Window Triple Panel flush to top of previously installed (209) Cross Brace and attach with two (YS4) #8 x 3” Wood Screws per side as shown in fig. 2.1. B: Place one (209) Cross Brace in between the posts, tight to the top of the (316) Window Triple Panel and attach with two (YS4) #8 x 3” Wood Screws per side as shown in fig. 2.1. Repeat for second assembly. 209 Fig. 2.
Step 3: Attach Arbor Side A: Place one (204) Arbor Side flush to the top and outside edge of (206) Engineered Panel Post, and attach with two (H4) 1/4 x 4” Hex Bolts (with flat washer, lock washer and t-nut) per side as shown in fig. 3.1. Repeat for second assembly. 1/4” t-nut 1/4” flat washer Fig. 3.1 1/4” lock washer 204 Flush H4 206 206 2x 204 Wood Parts Arbor Side 25.4 x 114.3 x 582.
Step 4: Assemble Arch Beam Assemblies A: Attach two (208) Arbor Ends flush to the top of (200) Arbor Arch Beam and centred over holes, using two (YS4) #8 x 3” Wood Screws per side. Ensure that you are using the outside holes as shown in fig. 4.1. Repeat for second assembly. Fig. 4.1 Flush Notice hole location on outside edge, on both sides of (200)Arbor Arch Beam. 208 YS4 200 208 YS4 2x 4x 200 208 Wood Parts Arbor Arch Beam 25.4 mm x 292.1 x 1746.3 mm Arbor End 25.4 x 114.
Step 5: Attach Arch Beam Assemblies A: Attach one Arch Beam Assembly, with (208) Arbor Ends facing out (fig. 5.1), flush to the top of and into (206) Engineered Panel Post assembly using 3 (H11) 1/4 x 2-3/4” Hex Bolts per side. (fig. 5.1) Repeat for second assembly. Flush 208 206 1/4” flat washer Fig. 5.
Step 6: Attach Arbor Trellis A: Attach one (203) Arbor Trellis centred on the top of both Arch Beam Assemblies, with two (YS24) #10 x 4” Wood Screws, as shown in fig. 6.1. B: Place two (203) Arbor Trellis on the outside edges of the arches. (See location of the Trellis labeled B in the image.) Attach using two (YS24) #10 x 4” Wood Screws per trellis as shown fig. 6.1. Fig. 6.
NOTES 13 support@yardistrystructures.
NOTES 14 support@yardistrystructures.
NOTES 15 support@yardistrystructures.
YARDISTRY Consumer Registration Card First Name Initial Last Name Street Apt. No.