User Guide
PREPARATIONS ➤ Optimizing the speaker settings automatically (YPAO) En 33
Error messages
If any error message is displayed during the measurement, resolve the problem and perform YPAO again.
TV screen
Front display
■ Procedure to handle errors
1
Check the content of error message and
press ENTER.
2
Use the cursor keys (e/r) to select the
desired operation.
To exit the YPAO measurement:
a Select “EXIT” and press ENTER.
b Use the cursor keys (q/w) to select “Exit” and press
ENTER.
c Disconnect the YPAO microphone from the unit.
To retry the YPAO measurement from
beginning:
Select “RETRY” and press ENTER.
To proceed with the current YPAO
measurement (for E-5 and E-9 only):
Select “PROCEED” and press ENTER.
Error
message
Auto Setup
Start
Exit
ERROR
E-5:Noisy
PROCEED
5%
VOL.
SW
L
SL
C
SR
R
E-5:NOISY
• Texts in parentheses denote indicators on the front display.
Error message Cause Remedy
E-1:No Front SP
(E-1:NO FRNT SP)
Front speakers are not detected.
Exit YPAO, turn off the unit, and then check the speaker
connections.
E-2:No Sur. SP
(E-2:NO SUR SP)
One of the surround speakers cannot be
detected.
E-4:SBR → SBL
(E-4:SBR -> SBL)
A surround back speaker is connected to
the R side only.
When using only one surround back speaker, you need to
connect it to the SINGLE jack (L side). Exit YPAO, turn off the
unit, and then reconnect the speaker.
E-5:Noisy
(E-5:NOISY)
The noise is too loud.
Keep the room quiet and retry YPAO. If you select
“PROCEED”, YPAO takes the measurement again and
ignores any noise detected.
E-6:Check Sur.
(E-6:CHECK SUR)
Surround back speakers are connected,
but no surround speakers are connected.
Surround speakers need to be connected in order to use
surround back speakers. Exit YPAO, turn off the unit, and
then reconnect the speakers.
E-7:No MIC
(E-7:NO MIC)
The YPAO microphone has been removed.
Connect the YPAO microphone to the YPAO MIC jack firmly
and retry YPAO.
E-8:No Signal
(E-8:NO SIGNAL)
The YPAO microphone cannot detect test
tones.
Connect the YPAO microphone to the YPAO MIC jack firmly
and retry YPAO. If this error occurs repeatedly, contact the
nearest authorized Yamaha dealer or service center.
E-9:User Cancel
(E-9:CANCEL)
The measurement has been canceled. Retry or exit YPAO as necessary.
E-10:Internal Err.
(E-10:INTERNAL)
An internal error has occurred.
Exit YPAO, and turn off and on the unit. If this error occurs
repeatedly, contact the nearest authorized Yamaha dealer or
service center.
1 2 3 4 5 6 7 8 9 10