MIDI Setup 225
01V—Owner’s Manual
versa. When using the TO HOST port, PORT should be set to match the type of com-
puter connected to the 01V, as follows.
Tx CH—This parameter determines which MIDI Channel the 01V uses to transmit
MIDI messages, and can be set from 1 through 16. The device receiving MIDI messages
from the 01V should be set to the same MIDI Channel. When the 01V transmits MIDI
data in response to a request, that data is transmitted on the same MIDI Channel that
the request was received on.
Rx CH—This parameter determines which MIDI Channel the 01V uses to receive
MIDI messages, and can be set from 1 through 16. The device transmitting MIDI mes-
sages to the 01V should be set to the same MIDI Channel. When PROGRAM CHANGE
OMNI or CONTROL CHANGE OMNI is turned on, program change and Control
Change messages can be received regardless of this setting.
PROGRAM CHANGE—Program Change messages are used to recall mix scenes. See
“Program Change Scene Recall” on page 227 for more information. The four ON/OFF
switches in this group are as follows.
Tx determines whether the 01V transmits Program Change messages when a mix scene
is recalled. Rx determines whether the 01V recalls mix scenes when Program Change
messages are received. OMNI determines whether the 01V receives Program Change
messages on all 16 MIDI Channels (ON) or just the Rx channel (OFF).
ECHO determines whether received Program Change messages are echoed through to
the MIDI OUT port. When ECHO is on, the 01V receives Program Change messages
and echoes them through to the MIDI OUT port regardless of the MIDI Channel set-
tings.
CONTROL CHANGE—Control Change messages are used to control 01V parameters
in real time. See “Control Change Parameter Control” on page 229 for more informa-
tion. The four ON/OFF switches in this group are as follows.
Tx determines whether the 01V transmits Control Change messages when mix param-
eters are adjusted. Rx determines whether the 01V adjusts mix parameters when Con-
trol Change messages are received. OMNI determines whether the 01V receives Control
Change messages on all 16 MIDI Channels (ON) or just the Rx channel (OFF).
ECHO determines whether received Control Change messages are echoed through to
the MIDI OUT port. When ECHO is on, the 01V receives Control Change messages
and echoes them through to the MIDI OUT port regardless of the MIDI Channel set-
tings.
PARAM. CHANGE—Parameter Change System Exclusive messages are used to con-
trol 01V parameters in real time. See “System Exclusive Parameter Control” on page 231
for more information. The three ON/OFF switches in this group are as follows.
Tx determines whether the 01V transmits Parameter Change System Exclusive mes-
sages when mix parameters are adjusted. Rx determines whether or not the 01V adjusts
mix parameters when Parameter Change System Exclusive messages are received.
When Rx is turned on, the 01V transmits Parameter Change System Exclusive messages
in response to requests even if Tx is turned off.
Setting Computer Platform Port Transmission Speed
MIDI
Standard MIDI MIDI IN, OUT, THRU 31.25 kbps
PC1
NEC PC9800 Series TO HOST 31.25 kbps
PC2
IBM PC compatible TO HOST 38.4 kbps
Mac