AUTO CHOKE SYSTEM
YES
NO
4. Thermo switch (auto choke)
Remove the thermo switch (auto choke)
from the radiator.
Connect the pocket tester ( × 1) to the
thermo switch 1 as shown.
Immerse the thermo switch in a container
filled with coolant 2.
NOTE:
Make sure that the thermo switch terminals
do not get wet.
Place a thermometer 3 in the coolant.
Slowly heat the coolant, then let it cool
down to the specified temperature.
Check the thermo switch for continuity at
the temperatures indicated in the table.
Test
step
Coolant temperature
Continu-
ity
Thermo switch
1
Less than 47 ± 3 °C
(116.6 ± 5.4 °F)
NO
2
More than 47 ± 3 °C
(116.6 ± 5.4 °F)
YES
3
More than 42 ± 3 °C
(107.6 ± 5.4 °F)
YES
4
Less than 42 ± 3 °C
(107.6 ± 5.4 °F)
NO
Steps 1 and 2: Heating phase
Steps 3 and 4: Cooling phase
WARNING
Handle the thermo switch with special
care.
Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
T
R
.
.
Thermo switch (auto choke)
30 Nm (3.0 m · kg, 22 ft · lb)
È
The thermo switch circuit is open and the auto
choke is off.
É
The thermo switch circuit is closed and the
auto choke is on.
Does the thermo switch operate properly
as described above?
Replace the thermo
switch (auto choke).