Service manual
3-6
INSP
ADJ
E
CONTROL SYSTEM
Shift cable inspection and adjustment
1. Check:
● Reverse gate stopper lever position
Incorrect → Adjust.
Checking steps:
● Set the shift lever to the reverse posi-
tion.
● Check that the reverse gate 1 contacts
the stopper 2 on the bracket and the
lever 3 contacts the reverse gate.
●
Set the shift lever to the forward posi-
tion.
●
Check that the lever 4 has been
shifted over the bracket 5.
4
5
2. Adjust:
● Shift cable joint
Adjustment steps:
● Loosen the locknut 1.
● Disconnect the cable joint 2 from the
ball joint 3.
● Situate the reverse gate to the stopper
on the bracket and the lever to the
reverse gate.
● Turn the cable joint to align it with the
ball joint.
Turn in Shortens.
Turn out Lengthens.
●
Turn out the cable joint nine times a
to extend cable 7 mm (0.28 in) from
the aligned position.
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
● Connect the cable joint and tighten the
locknut.
T
R
.
.
Locknut:
3 N • m (0.3 kgf • m, 2.2 ft • lb)