Setup — Rack mounting
11
PX10/PX8/PX5/PX3 Reference Manual
The PX amplifier can be mounted in an EIA standard rack
(2U size).
Rack mounting
Precautions for rack mounting
This device is rated for operation at ambient tempera-
tures ranging from 0° to 40°C. When mounting the device
with other device(s) in an EIA standard equipment rack,
internal temperatures can exceed the specified upper
limit, resulting in impaired performance or failure. When
rack mounting the device, always observe the following
requirements to avoid heat buildup:
• When mounting the unit in a rack with devices such as
power amplifiers that generate a significant amount of
heat, leave more than 1U of space between the device
and other equipment. Also, either leave the open
spaces uncovered or install appropriate ventilating pan-
els to minimize the possibility of heat buildup. Multiple
PX amplifiers can be mounted by stacking vertically.
• To ensure sufficient airflow, leave the rear of the rack
open and position it at least 10 centimeters from walls
or other surfaces. If the rear of the rack cannot be left
open, install a commercially available fan or similar ven-
tilating option to secure sufficient airflow. If you have
installed a fan kit, there may be cases in which closing
the rear of the rack will produce a greater cooling effect.
Refer to the rack and/or fan unit manual for details.
Connecting to the [SPEAKERS] termi-
nal
Binding post connector
• Without plugs
Remove about 15 mm of insulation from the end of
each speaker cable, pass the bare wire through the holes
in the appropriate speaker terminals, and tighten the ter-
minals to securely clamp the wires. Make sure that the
bare wire ends do not jut out from the terminals and
touch the chassis.
• Y-plugs
From above, insert the Y-plugs all the way into the
opening, and tighten the terminal.
speakON connector
Insert the speakON cable plug (Neutrik NL4) into the
connector, and turn it to the right to lock it.
Speaker connection
CAUTION
Make sure that the power is turned off, to avoid the dan-
ger of electrical shock.
15 mm
0.25"
(6.3 mm)
≤0.51"
(12.9 mm)
1+
1–
2–
2+
Channel A
Neutrik NL4 PX amplifier
1+ A+
1– A–
2+ B+
2– B–
Channel B
Neutrik NL4 PX amplifier
1+ B+
1– B–
2+ (not connected)
2– (not connected)