The DME24N, DME8o-C and DME4io-C have analog outputs. The DME24N and DME8i-C have eight
analog outputs, while the DME4io-C has four.
SP2060 Input and Output
The SP2060 configuration window includes [SP2060 Input] and [SP2060 Output] blocks.
SP2060 Input
Either double-click [SP2060 Input] or select [Open Component Editor] from the contextual menu that
appears when the component is right-clicked to open the editor.
Name/Parameter Range Function
1 Input Select Analog IN A/B
Selects analog input channels A and B
as the input signal sources.
Analog IN A/A
Selects analog input channel A as the
source for both input signals.
Digital IN L/R
Selects digital input channels L and R
as the input signal sources.
Digital IN L/L
Selects the digital L input channel as the
source for both signals.
Selects the input signal(s).
2 Input Level -~ +10 dB Set the input signal level for the
corresponding input channel.
3 Meter - Display the input signal level for the
corresponding input channel.
4 Mute ON/OFF Mute the input of the corresponding input
channel.
1
23
4