Owner's Manual

Chapter 4 Designer
DME Designer Owner’s Manual
277
Configuration Window
The Configuration window is used for arranging components on the sheet and making logical
connections. It is displayed when you double-click on a DME or SP2060.
Title Bar
Displays “Device Name (Zone Name).” The configuration window for a DME64N placed in [Zone1]
will be “DME64N (Zone1).” The device name is set in the properties for the device placed in the
Zone window.
Objects
Objects such components, user modules, and shapes are arranged in the Configuration window.
When you double-click a component placed in the window, the editor set in “Double Click Action”
in “User Module Properties” will open.
I/O Component
Depending on the settings for the DME placed in the Zone window, I/O components will be
automatically placed or added.
I/O components can be arranged in the DME24N/DME8i-C/DME8o-C/DME4io-C and SP2060
configuration window.
When “Show Cascade Port” is ON in the DME64N “DME Device Properties” dialog, Cascade I/O
is added automatically.
When you set a slot in the properties for a DME placed in the Zone window, Slot I/O will be
automatically added.
You cannot apply edit operations like cut/copy/paste/duplicate to I/O components, Slot I/O, and
Cascade I/O.
NOTE
SP2060 configurations cannot be edited.
Tool Bar
Sheet
Legend
User Module
Component
Wire
I/O Component