F OUTPUT SAFE PARAMETERS
In this area you can view and edit the Recall Safe settings for all output channels. The items in this area are the
same as in the Input Safe Parameters area (
1).
G GLOBAL RECALL SAFE
In this area you can view and edit the Recall Safe settings for patching, DCA groups, and racks.
H INPUT PATCH
This on/off button specifies whether INPUT PATCH settings will be excluded from recall operations.
I INPUT NAME
This on/off button specifies whether the channel names of input channels will be excluded from recall operations.
J OUTPUT NAME
This on/off button specifies whether the channel names of output channels will be excluded from recall opera-
tions.
K OUTPUT PATCH
This on/off button specifies whether OUTPUT PATCH settings will be excluded from recall operations.
L DCA
These buttons exclude DCA groups from recall operations. If the ALL button is on, the LEVEL, ON, and DCA
group names will be excluded. If the LEVEL/ON button is on, LEVEL and ON settings will be excluded.
M RACK
This on/off button specifies whether RACK settings will be excluded from recall operations.
N SET ALL
This button switches on all buttons for parameters 8–13.
O CLEAR ALL
This button switches off all buttons for parameters 8–13.