Service manual

ELEC
101
\
Checking the fail-safe relay
1. Check:
solenoid relay for continuity
Connect the pocket tester ( × 1) to the ter-
minals.
Check for continuity between terminals
and of the solenoid relay.
Tester positive probe Terminal
Tester negative probe Terminal
Tester reading is “ ”. Replace the fail-
safe relay.
Check for continuity between terminals
and of the solenoid relay.
Tester positive probe Terminal
Tester negative probe Terminal
Tester reading is “ ”. Replace the fail-
safe relay.
Connect the positive battery terminal to ter-
minal and the negative battery terminal
to terminal , and then check for continuity
between terminals and of the sole-
noid relay.
Tester positive probe Terminal
Tester negative probe Terminal
Tester reading is “ ”. Replace the fail-
safe relay.
CAUTION:
When connecting the solenoid relay and
battery terminals, be careful not to short-
circuit the positive and negative battery ter-
minals.
Fail-safe relay
ABS motor relay
Solenoid relay
Solenoid relay resistance
150 ~ 450
Operation of solenoid relay
Terminal number
Continuity
Normal
condition
Connect the
battery to
terminals
and
ANTI-LOCK BRAKE SYSTEM (ABS)