Owner's Manual

References
SP2060 Owner’s Manual
Foreword
Network Settings ReferencesPanel Operation
Introduction
to the SP2060
The Controls
and Connectors
44
Display Messages
Warning and error messages
* Do NOT turn off the power to the SP2060 while the unit displays the message “DO NOT TURN OFF!” at the bottom of the display.
Message Meaning Action
Duplicate IP Adr. Duplicate IP addresses. Change the IP addresses so that there are no duplicates.
Illegal MAC Adr. An illegal MAC address has been encountered.
This could be due to a hardware malfunction. Refer this
problem to a contact a Yamaha dealer.
Invalid IP Adr. The IP address is not set properly. Set an appropriate network IP address.
Network Error
A cable is disconnected, the power to the
connected switching hub or router is turned off, or a
cable is not in proper condition.
Connect the cables properly, and make sure that the hub
and/or router are operating correctly.
No MAC Adr. MAC address not specified.
This could be due to a hardware malfunction. Refer this
problem to a Yamaha dealer.
No Battery
The internal battery is completely discharged or not
installed.
If you turn off the power to the unit, the current settings will
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer for battery replacement.
Critical Battery
The internal battery is almost discharged. Your data
may be lost.
If you turn off the power to the unit, the current settings may
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer for battery replacement.
Low Battery The backup battery voltage is low.
This does not affect the operation of the unit. However, if you
continue using the unit, the settings may be lost and reset to
the default values. Contact a Yamaha dealer for battery
replacement at your earliest convenience.
Recovering
A program update attempt has failed, and the
previous program is currently being restored.
Do NOT turn power off while the unit is displaying this
message. If the update attempt repeatedly fails, there may
be a hardware malfunction. Refer this problem to a Yamaha
dealer.
Scene Recall Err A scene recall attempt has failed.
Recall the scene again.
If the problem persists, contact a Yamaha dealer.
Saving Failed A save operation has failed.
This could be due to a hardware malfunction. Refer this
problem to a Yamaha dealer.
Param Access Err Current setting cannot be displayed. Save the current setting by using DME Designer, then
initialize the unit. If the problem persists, contact a Yamaha
dealer.
Param Set Err Current setting cannot be changed.
W.Clk Unlocked
A usable word clock signal is not being received or
cannot be detected.
Recheck all word clock connections and internal
parameters.
DevGrp Sync Err
The device group configuration set via DME
Designer does not match the real configuration.
Use DME Designer to go off-line, create a configuration that
correctly matches the actual configuration, and then go
back on-line to synchronize the configuration.
System Error A system error has occurred.
Save the current setting by using DME Designer, then
initialize the unit. If the problem persists, contact a Yamaha
dealer.