Control I/O standards
Dimensions (WxHxD), weight
480mm × 232mm × 490mm (including the rubber feet), 20kg
Accessories
Owner’s Manual, AC power cords (x2), Euroblock plug (three-pin)
Optional items
Mini-YGDAI card, HY card
EIA rack mount size
5U
NC value
Low mode: NC=15 / High mode: NC=20
Measuring position: 100cm away from the units front panel
Terminals Format Level Connectors
Balanced /
Unbalanced
MIDI IN MIDI DIN 5pin
OUT MIDI DIN 5pin
TC IN SMPTE
SMPTE
0.3Vpp (Min.) /
10.0Vpp (Max.), 10kΩ
XLR-3-31 type
*1
*1. 1= GND, 2= HOT, 3= COLD
Balanced
WORD CLOCK IN TTL/75Ω terminated BNC
OUT TTL/75Ω BNC
GPI D-SUB (25-pin, female)
*2
*2. Inputs
CH 1-7: TTL logic (input voltage: 0-5V)
CH 8: Optocoupler (input voltage: 0-24V / Low level ≤1V, High level: ≥5V)
Outputs
CH 1-7: Open-drain (Max. external supply voltage= 12V, Max. sink current per pin= 75mA)
CH 8: Relay Contact (Max. 1A/30VDC)
Power Supply Pins (5V ±5%, Max. total output current= 600 mA)
REMOTE RS422 / 232C
*3
*3. Toggled by the switch.
D-SUB (9-pin, male)
FAULT OUTPUT NO < DC30V, < 1A Euro Block Connector 3P
C
*4
*4. The C terminal normally short-circuits with the NC terminal, but it short-circuits with the NO terminal in the event that a fault is detected.
––
NC < DC30V, < 1A
TO CONSOLE IN/OUT 1000BASE-T etherCON CAT5e
*5
*7
*5. CAT5e or higher cables are recommended for connection.
NETWORK IEEE802.3 10BASE-T/100BASE-TX etherCON CAT5
*6
*7
*6. CAT5 or higher cables are recommended for connection.
*7. STP cables are recommended for connection.
NETWORK [PC] IEEE802.3 10BASE-T/100BASE-TX etherCON CAT5
*6 *7