If a problem occurs in the XMV, the [ALERT] indicator will flash and an alert number will appear in the display.
The alert numbers, the corresponding content, and the appropriate actions are listed below.
Alert Numbers and Content
Alert number Meaning Response
No display
(only [ALERT] is lit)
The device has not started up correctly.
Turn the power off, then turn on after waiting at least 5
seconds. If this does not solve the problem, please ini-
tialize the memory. Should this also fails, contact your
Yamaha dealer.
001.–008.
010.
The internal backup battery has been completely
exhausted or is not installed.
When you turn off the power, the current settings will be
lost, and will return to the default values. Please stop use
immediately, and contact your Yamaha dealer.
011.
The internal backup battery has run extremely low, and
it is possible that the internal memory has been cleared.
012.
The internal backup battery has only a small amount of
power remaining.
This does not affect the operation of the device. How-
ever, if y
ou continue using the device, the settings may
be lost and reset to the default values. Contact your
Yamaha dealer as soon as possible.
013.
A problem has occurred with the internal clock, and it
has been initialized (January 1, 2000, 0:00)
If this occurs each time you turn on the power, it is possi-
ble that the internal backup battery has run down or that
the device has malfunctioned. Contact your Yamaha
dealer.
If this occurs only once, an abnormality was detected
with the clock setting and it was initialized; use the editor
to set the time.
015. The settings saved in internal memory have been lost.
Either the internal backup battery has run low, or the
device has malfunctioned
. Cont
act your Yamaha dealer.
016. A memory problem has occurred. Contact your Yamaha dealer.
021. The word clock master has become unlocked.
Make sure that the word clock signal is being input cor-
rectly.
022.
The digital signal being input to the [YDIF IN] connector
is not synchronized to the word clock of this device.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
023.
The digital signal being input to the [YDIF IN] connector
is not continuously synchronized to the word clock of
this device.
030.
There is a problem with the connection of the [YDIF IN]
connector.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
040. Duplicate IP addresses.
Change the IP addresses so that there are no dupli-
cates.
041. IP address was not set within 60 seconds of startup.
Please check rear panel DIP s
witch 6 (IP Set
ting). If D
IP
switch 6 is set to “PC,” use the editor or DHCP server to
specify the device IP address.
043. Too many devices are connected to the network.
Reduce the number of devices connected to the net-
work.
046. Dante transmission flow count exceeded the limit.
Maximum Dante Flow rate exceeded. Try changing parts
of transmission flows to Multicast using Dante Controller.
050. The UNIT ID is set to “00.” Set the UNIT ID to something other than “00.”
051.
Devices with identical UNIT IDs were found connected
within the same network.
Change the UNIT ID so that there are no duplicates.
072.
Because this device has Dante Device Lock enabled,
the settings of device DIP switches and MTX-MRX Edi-
tor do not match current Dante settings.
If you have Dante Device Lock enabled, please disable
using Dante Controller, review device DIP switch settings
and MT
X-MRX Editor
’s Dante settings, and edit as nec-
essary to match the current situation.
100.
The power supply was shut down because d.c. was
detected on a speaker output.
It is likely that the device has malfunctioned; immediately
stop using the device and contact your Yamaha dealer.