User Manual

Alert
number
Meaning Response
24 The digital signal being input to the slot is
not synchronized to the word clock of this
device.
Either input a signal that is synchronized, or specify the
slot as the word clock leader.
25 The digital signal being input to the slot is
not continuously synchronized to the word
clock of this device.
26 The digital signal being input to the Dante
connector is not synchronized to the word
clock of this device.
Either input a signal that is synchronized, or specify the
Dante as the word clock leader.
27 The digital signal being input to the Dante
connector is not continuously synchronized
to the word clock of this device.
28 The Dante sampling frequency has been
changed to match the word clock leader of
this unit.
Check the word clock setting of this unit. Then set the
sampling frequency of the Dante network.
30 There is a problem with the connection of
the [YDIF IN] connector.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
40 Duplicate IP addresses. Change the IP addresses so that there are no
duplicates.
41 IP address was not set within 60 seconds
of startup.
Please check rear panel DIP switch 6 (IP Setting). If DIP
switch 6 is set to “PC,” use ProVisionaire Design or
DHCP server to specify the device IP address.
42 A device within the MTX system was not
found on the network.
Power-on all devices in the system, and make sure that
they are correctly connected to the network.
43 Too many devices are connected to the
network.
Reduce the number of devices connected to the
network.
46 Dante transmission flow count exceeded
the limit.
Maximum Dante Flow rate exceeded. Try changing
parts of transmission flows to Multicast using Dante
Controller.
50 The UNIT ID is set to “00.” Set the UNIT ID to something other than “00.”
51 Devices with identical UNIT IDs were found
connected within the same network.
Change the UNIT ID so that there are no duplicates.
52 A communication error occurred with the
[DCP] connection.
• If an error was shown in the DCP panel, refer to the
DCP owner’s manual and take the appropriate action.
• Ensure that the panel ID of the DCP units do not
conflict.
• Verify that the cables are correctly connected and are
within the specified length.
53 [The DCP connected to the [DCP] connector
has been configured differently from the
project settings.
• Check that the required DCP is connected.
• Check whether a different model of DCP might be
connected.
56 SD memory card was not recognized. Use an SD memory card that complies with the
specifications.
14. Audio Processors : MTX5-D/MTX3
210 | ProVisionaire Design User Guide