14.8. Alert list
The alerts generated by MTX5-D/MTX3 units, and their significance and the appropriate actions, are listed below.
If the problem is not solved, please contact your Yamaha dealer.
Alert
number
Meaning Response
01–09 The device has not started up correctly. Turn the power off, then turn on after waiting at least 6
seconds. If this does not solve the problem, please
initialize the memory. Should this also fails, contact
your Yamaha dealer.
10 The internal backup battery has been
completely exhausted or is not installed.
When you turn off the power, the current settings will
be lost, and will return to the default values. Please
stop use immediately, and contact your Yamaha
dealer.
11 The internal backup battery has run
extremely low, and it is possible that the
internal memory has been cleared.
When you turn off the power, the current settings will
be lost, and will return to the default values. Please
stop use immediately, and contact your Yamaha
dealer.
12 The internal backup battery has only a
small amount of power remaining.
This does not affect the operation of the device.
However, if you continue using the device, the settings
may be lost and reset to the default values. Contact
your Yamaha dealer as soon as possible.
13 A problem has occurred with the internal
clock, and it has been initialized (January 1,
2000, 0:00).
If this occurs each time you turn on the power, it is
possible that the internal backup battery has run down
or that the device has malfunctioned. Contact your
Yamaha dealer.
If this occurs only once, an abnormality was detected
with the clock setting and it was initialized; use
ProVisionaire Design to set the time.
14 The current preset saved in internal
memory has been lost.
Recall the preset. If this does not solve the problem,
contact your Yamaha dealer.
15 The settings saved in internal memory have
been lost.
Either the internal backup battery has run low, or the
device has malfunctioned. Contact your Yamaha
dealer.
20 An unsupported Mini-YGDAI card is inserted
in the slot, or the inserted Mini-YGDAI card
has malfunctioned.
Replace the card with a supported Mini-YGDAI card or
check that the supported Mini-YGDAI card is working
correctly in another Host.
21 The word clock leader has become
unlocked.
Make sure that the word clock signal is being input
correctly.
22 The digital signal being input to the [YDIF
IN] connector is not synchronized to the
word clock of this device.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
23 The digital signal being input to the [YDIF
IN] connector is not continuously
synchronized to the word clock of this
device.
14. Audio Processors : MTX5-D/MTX3