User Manual

14.7.6. "Recall Settings" dialog box
Click on [Recall Settings] in the "Presets" area of the device sheet to open this.
Configures settings related to the DCP library and External Event that are recalled at the same time when a
preset is recalled.
DCP Library
Selects the DCP library to be recalled at the same time when a preset is recalled.
External Event
Selects the Event to be output at the same time when a preset is recalled.
Select the event number set in the “External Events” dialog box.
GPI Out
Configures the GPI OUT setting that is output at the same time when a preset is recalled.
An external device connected to the [GPI OUT] terminal on the main unit is controlled using the output of
GPI OUT.
[Active]/[Inactive]/[Ignore] button
Specify whether the GPI OUT connector’s output will be enabled (Active), enabled with the OUTPUT TYPE
inverted (Inactive), or ignored (Ignore).
If the [OUTPUT TYPE] in the GPI Output dialog is set to [Pulse] or [Pulse Inv.], only [Active] or [Ignore] can
be selected.
If in the “Settings” dialog box, the [OUTPUT TYPE] setting is set to [Pulse] or [Pulse Inv.], the only available
choices will be [Active] and [Ignore].
If [Active] is specified
When [OUTPUT TYPE] is [ Closed], the [GPI OUT] pin will be closed (connected to ground).
When [OUTPUT TYPE] is [ Open], the [GPI OUT] pin will be open.
When [OUTPUT TYPE] is [ Pulse], the [GPI OUT] pin will be closed (connected to ground) for
approximately 250 ms.
When [OUTPUT TYPE] is [ Pulse Inv.], the [GPI OUT] pin will be open for approximately 250 ms.
If [Inactive] is specified
When [OUTPUT TYPE] is [ Closed], the [GPI OUT] pin will be open.
When [OUTPUT TYPE] is [ Open], the [GPI OUT] pin will be closed (connected to ground).
If [Ignore] is specified
14. Audio Processors : MTX5-D/MTX3
ProVisionaire Design User Guide | 203