XMV4280/XMV4140/XMV4280-D/XMV4140-D Owner’s Manual
29
Warnings and certain other types of information are displayed via the XMV4280-D/XMV4140-D front panel indicators.
Messages are also displayed in the Dante Controller Error Status field.
Each indicator lights or flashes as described below:
Information Messages
The status is shown by the lit/flashing state of the indicator.
If the orange [SYNC] indicator is unlit, the unit is operating normally.
If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed.
Warning Messages
The indicator will remain lit or continue flashing cyclically until the problem is solved.
If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed.
If the green indicator is flashing, the unit is the clock master.
If the green indicator is lit, the unit is the clock slave and the clock is synchronized.
Dante Messages (XMV4280-D/XMV4140-D only)
Unlit The indicator is off.
Lit The indicator remains lit steadily.
Flash The indicator continues to flash.
Flash x 2 The indicator flashes twice cyclically.
SYNC Indicators Description Explanation
Synchronization is occurring.
Please wait until the unit synchronizes
completely. It may take approximately 60
seconds for synchronization to be com-
pleted.
The unit is functioning correctly as the word clock
master.
The unit is operating as the word clock
master.
The unit is functioning correctly as the word clock
slave.
The unit is operating as the clock slave
and the clock is synchronized.
SYNC Indicators Description Possible Solution
The word clock is not set correctly.
Set the clock master and sampling fre-
quency correctly on the MTX-MRX Editor
or in Dante Controller.
Dante Network circuit is broken.
Make sure that the Ethernet cables are
not removed or short-circuited.
SYNC Indicators Description Possible Solution
A non-GbE-compatible device is connected.
When transferring audio via Dante, use
device that supports GbE.
The Dante [SECONDARY] connector has taken
over communications during redundant network
operation.
Check the circuit connected to the Dante
[PRIMARY] connector.
An abnormality has occurred on the circuit con-
nected to the Dante [SECONDARY] connector dur-
ing redundant network operation.
Check the circuit connected to the Dante
[SECONDARY] connector.
(green) Unlit
(orange) Lit
(green) Flash
(orange) Unlit
(green) Lit
(orange) Unlit
(green) Unlit
(orange) Flash
(green) Unlit
(orange) Flash x2
(green) Lit or flash
(orange) Lit
(green) Lit or flash
(orange) Flash
(green) Lit or flash
(orange) Flash x 2