XMV4280/XMV4140/XMV4280-D/XMV4140-D Owners Manual
24
Parameter Operations
*2: “XY” means “operate X, and then operating Y.” For example, “[SELECT] A encoder” means that you should press the [SELECT]
A, and then operate the encoder.
To do this...
Operating mode
(indication)
Operation Description
Changing the attenuator
value (volume)
attenuator
(ATT)
[SELECT] (of the channel to
be changed) encoder
*2
The [SELECT] indicator of the selected channel
will lit, and the attenuator value can be edited by
the encoder.
The range of adjustment is -99 dB–0 dB in 1 dB
steps.
Changing the polarity
polarity
(POL)
[SELECT] (of the channel to
be changed) encoder
*2
The [SELECT] indicator of the selected channel
will light, and the polarity can be changed by using
the encoder.
Changing the high pass fil-
ter (HPF) cutoff frequency
Turning off the high pass
filter (HPF)
HPF
(HPF)
[SELECT] (of the channel to
be changed) encoder
*2
The [SELECT] indicator of the selected channel
will light, and the high pass filter (HPF) on/off set-
ting and cutoff frequency can be changed by using
the encoder. This will be set to 80 Hz if a high
impedance connection is specified; it will be turned
OFF if a low impedance connection is specified.
In order to protect the amplifier, the HPF of the
selected channel cannot be turned OFF if a high
impedance connection is specified.
Switching between analog/
digital input
analog/digital input
selection
(SRC)
Encoder operation
The [SELECT] indicator of the selected channel
will light, and you can use the encoder to change
the analog/digital input selection.
Do not select “analog” if your audio network has
been configured using the [YDIF] connectors or
Dante [PRIMARY]/[SECONDARY] connectors.
Selecting “analog” will interrupt audio transmission
to and from the devices that are connected via the
YDIF connectors or Dante connectors.
Switching whether the
[SIGNAL] indicators are
used for input or for output
[SIGNAL] indicator
switching
(SIG)
Enco
der opera
tion
Use the encoder to specify whether the [SIGNAL]
indicators will show the input signal level or the out-
put signal level.
Digital input sensitivity
selection
* Digital input sensitivity: the
digital input level at which
the input attenuator is 0 dB
(volume maximum) and the
amplifier is at maximum
output; refer to “Block Dia-
gram” (page 236).
digital input
sensitivity
(DIS)
Encoder operation
Use the encoder to change the digital input sensi-
tivity setting. To prevent inadvertent setting, the
value does not change right away when the
encoder is turned. Until the input sensitivity
changes, “
–––” appears in the display.
Indication Polarity
NOR Normal polarity
INV Inverted polarity
Indication Meaning
OFF HPF is off
H40 Cutoff frequency is 40 Hz
H80 Cutoff frequency is 80 Hz
Indication Input connectors
ANA Analog input connectors
DIG
[YDIF] connectors
(XMV4280/XMV4140)
Dante [PRIMARY]/
[SECONDARY] connectors
(XMV4280-D/XMV4140-D)
Indication Lit condition
IN Input
OUT Output
Indication Digital input sensitivity
D20 -20 dBFS
D03 -3 dBFS
–––
(value in process of being
changed)