User Manual

Connections and Setting Up
XMV4280/XMV4140/XMV4280-D/XMV4140-D Owners Manual
22
Connecting the [REMOTE] Connector or
[FAULT OUTPUT] Connector
You must use the supplied Euroblock plugs when making con-
nections to the [REMOTE] connector or [FAULT OUTPUT]
connector.
If these have been lost, please contact your Yamaha dealer.
1. Loosen terminal screws.
2. Insert cables.
3. Securely tighten terminal screws.
Pull the cables (not too strongly) to confirm that they are
securely connected.
4. Insert the Euroblock plug into the [REMOTE]
connector or [FAULT OUTPUT] connector of
the device.
Cable preparation
To prepare the cable for attachment to a Euroblock
connector, strip the wire as shown in the illustration
using stranded wire to make connections. With a Euro-
block connection, stranded wires may be prone to
breakage because of metal fatigue due to the weight of
the cable or due to vibration.
•If cables will be frequently connected and discon-
nected, as in the case of a portable installation, we
recommend that you use ferrules with insulation
sleeves. Use a ferrule whose conductor portion has an
external diameter of 1.3 mm or less, and a length of
approximately 5 mm (such as the AI0,5-6WH made by
the Phoenix Contact corporation).
NOTE
A slotted screwdriver with a blade width of about 3 millime-
ters is recommended.
approx.
5 mm
NOTE
Do not tin (plate with solder) the exposed end.
1.3 mm or less
approx.
5 mm
Loosen.
Terminal
screw
Slotted screwdriver
Euroblock plug
3 mm or less