User Manual
Table Of Contents
22
Owner’s Manual
Messages
Messages
Errors, warnings, and certain other types of information
are displayed via the RSio64-D front panel indicators.
Messages are also displayed in the Dante Controller Error
Status field.
Each indicator lights or flashes as described below:
Error Messages
If one of the following errors has occurred, the device will
not operate. Until the error is resolved, the green SYSTEM
indicator will be turned off, and all indicators for all I/O
channels will continue to flash.
In addition, certain errors will cause the red SYSTEM
indicator to light or flash.
The following errors affect the settings or the hardware.
However, the device will still be usable. The green
SYSTEM indicator will light, and all indicators for all I/O
channels will work normally.
In addition, certain errors will cause the red SYSTEM
indicator to light or flash.
No call-out The indicator is off.
Light The indicator remains lit steadily.
Flash The indicator continues to flash.
Flash x2 The indicator flashes twice cyclically.
Flash x3 The indicator flashes three times cyclically.
[SYSTEM] Indicators Description Possible Solution
An internal error
has occurred.
The device has
failed. Contact
your Yamaha
dealer for repair.
Communication
cannot occur
because the MAC
address setting
has been cor-
rupted.
UNIT ID is not
unique.
Set a unique UNIT
ID number within
the Dante network.
The device’s DIP
switches are not
set correctly.
Check the DIP
switch settings,
and set them cor-
rectly.
(red)
Flash x2
(red)
Flash x3
(red)
Lit
(red)
Flash
[SYSTEM] Indicators Description Possible Solution
The number of
Dante transmit
flows exceeded the
limit.
Reduce the num-
ber of flows by, for
example, using
Dante Controller to
change some of
the transmit flows
to multicast.
The cooling fan
has stopped.
Check that noth-
ing is caught in the
fan. If the problem
persists, consult
your Yamaha
dealer.
The internal mem-
ory has been cor-
rupted.
When using the
unit in [NORMAL]
mode, if the prob-
lem persists even
after turning the
power off and on
again, consult your
Yamaha dealer.
Yo u changed the
positions of the
device setting DIP
switches or rotary
switch, or changed
the Dante settings
from Dante Con-
troller. Therefore,
the positions of the
device setting DIP
switches do not
match the act
ual
D
ante settings.
If the Device Lock
setting was
enabled from
Dante Controller,
disable the setting,
or check the
device setting DIP
switch positions,
and set them to
accommodate the
current situation.
(red)(green)
Lit Flash
(red)
Flash x2
(green)
Lit
(red)
Flash x3
(green)
Lit
(red)(green)
LitLit