MTX3, MTX5-D, MRX7-D, XMV Series, EXi8, EXo8 Remote Control Protocol Specifications Version 2.2.0 rev8 Release Jun 21st, 2016 This specification document applies to MTX3, MTX5-D, MRX7-D, XMV, EXi8, and EXo8 V2.20 and later.
0. Revision History Version V1.0.0 V1.0.1 Date Sep. 1, 2013 Sep. 25, 2013 V1.0.2 Jan.14, 2014 V1.0.3 May 23, 2014 V1.3.0 Nov. 1, 2014 V2.0.3 Aug. 25, 2015 V2.1.0 Dec. 22, 2015 Section 7 7 8 3.1 3.1 3.2.4 3.2.4, 3.4.3 3.2.4, 3.4.3 3.3.1 3.3.3 3.4.3 4 4 6 7 7 7 8 3.3.
0. Revision History Version V2.2.0 Date Jun.
1. Setup 1.1. Connection Procedure Connection when using the NETWORK connector to perform remote control using this protocol MTX3 Remote Controller Ethernet Network Switch Ethernet Ethernet Network Switch Ethernet Ethernet Network Switch Ethernet MTX5-D Remote Controller MRX7-D Remote Controller * Also for XMV, EXi8 and EXo8. XMV can be controlled with the protocol in this document without MTX3, MTX5-D or MRX7-D.
1. Setup 1.2. Configuring the Remote Controller MTX3, MTX5-D and MRX7-D can be controlled from an external controller through the Ethernet (NETWORK) connector and RS-232C (REMOTE) connector. XMV, EXi8 and EXo8 can be controlled from an external controller through the Ethernet (NETWORK) connector. The configuration on the remote controller side for each type of connection is shown below. Ethernet (NETWORK connector) control IP Address: Specify the IP address of the device you want to control. IP Port No.
1. Setup 1.3. Device Configuration 1.3.1. MTX3, MTX5-D and MRX7-D MTX3, MTX5-D and MRX7-D can be controlled from an external controller through a NETWORK and RS-232C connector. Up to nine remote controller devices can connect simultaneously to one MTX or MRX device, eight via the NETWORK connector and one via the RS232 connector. The procedure to configure the second control port of MTX3, MTX5-D and MRX7-D is shown below, this is found in MTX-MRX Editor - System Menu- > Remote control.
2. Command List 1. Commands from a device sent to a remote controller No.
2. Command List 3. Extended commands No.
3. Command Specifications 3.1. Basic Command Specifications Below is the syntax of commands exchanged between a device and remote controller.
3. Command Specifications 3.2. Commands a Device Sends to a Remote Controller 3.2.1. Device status change notification 1-1) Device run mode notification Command NOTIFY devstatus Example: Option 1 runmode Option 2 "emergency" "update" "normal" Description Emergency run mode Update mode Normal run mode Notification: NOTIFY devstatus runmode "normal" Meaning: The run mode was changed to normal mode.
3. Command Specifications 3.2.2.
3. Command Specifications 1-7) Parameter change notification MTX3,MTX5-D,XMV,EXi8,EXo8 Command NOTIFY mtr Option 1 MTX:mtr_MemNo/UniqueId/meter MTX:mtr_MemNo/UniqueId/hold Details: Option 2 level gr hold Option 3 (meter) Description Level meter value gr meter value Hold meter value MemNo = See section 8, "Meters." UniqueId = See section 8, "Meters." (meter) = See section 5, "Meter Values.
3. Command Specifications 3.2.4.
3.
3.
3. Command Specifications 3.3. Commands for controlling a device 3.3.1. Device status query 2-1) Device run mode query Command Option 1 devstatus runmode Description Queries the run mode Response Response string OK devstatus runmode "emergency" OK devstatus runmode "update" OK devstatus runmode "normal" Example: Command: Response: Meaning: Note: Description Emergency run mode Update mode Normal run mode devstatus runmode OK devstatus runmode "normal" Query the run mode.
3. Command Specifications 2-3) Current Fs (sampling frequency) status query Command Option 1 devstatus fs Description Queries Fs Response Response string OK devstatus fs "unknown" OK devstatus fs "44.1kHz" OK devstatus fs "48kHz" Example: Command: Response: Meaning: Description Fs undefined 44.1kHz 48kHz devstatus fs OK devstatus fs "44.1kHz" Query Fs. The current Fs is 44.1 kHz.
3. Command Specifications 3.3.3.
3. Command Specifications 2-9) Keepalive activation setting Command scpmode Option 1 keepalive Option 2 (interval) Details: (interval) = Timeout value (msec) Description Maximum interval for a client to send some kind of message, including heart beats (default setting = disabled) * Timeout value should be more than 1000. * The actual timeout value will be increased by 1 second.
3. Command Specifications 3.3.4. Parameter query 2-10) Raw value parameter query MTX3,MTX5-D,XMV,EXi8,EXo8 Command get Details: Option 1 MTX:mem_MemNo/UniqueId/ElmNo/Xpos/ Ypos/PrmNo/IndexNo MemNo = UniqueId = ElmNo = Xpos = Ypos = PrmNo = IndexNo = Option 2 0 Option 3 0 Description Raw value parameter query request See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values.
3. Command Specifications 2-11) Normalized value parameter query MTX3,MTX5-D,XMV,EXi8,EXo8 Command getn Details: Option 1 MTX:mem_MemNo/UniqueId/ElmNo/Xpos/ Ypos/PrmNo/IndexNo MemNo = UniqueId = ElmNo = Xpos = Ypos = PrmNo = IndexNo = Option 2 0 Option 3 0 Description Normalized value parameter query request See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values.
3. Command Specifications 3.3.5. Parameter setting 2-13) Raw value parameter setting MTX3,MTX5-D,XMV,EXi8,EXo8 Command set Details: Option 1 MTX:mem_MemNo/UniqueId/ElmNo/ Xpos/Ypos/PrmNo/IndexNo MemNo = UniqueId = ElmNo = Xpos = Ypos = PrmNo = IndexNo = (value) = Option 2 0 Option 3 0 Option 4 (value) Description Raw value parameter setting See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values.
3. Command Specifications 2-14) Normalized value parameter setting MTX3,MTX5-D,XMV,EXi8,EXo8 Command setn Details: Option 1 MTX:mem_MemNo/UniqueId/ElmNo/ Xpos/Ypos/PrmNo/IndexNo MemNo = UniqueId = ElmNo = Xpos = Ypos = PrmNo = IndexNo = (value) = Option 2 0 Option 3 0 Option 4 (value) Description Normalized value parameter setting See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values.
3. Command Specifications 2-15) Relative value parameter setting MTX3,MTX5-D,XMV,EXi8,EXo8 Command setr Option 1 MTX:mem_MemNo/UniqueId/ElmNo/ Xpos/Ypos/PrmNo/IndexNo Details: MemNo = UniqueId = ElmNo = Xpos = Ypos = PrmNo = IndexNo = "(value)" = Note: Option 2 0 Option 3 0 Option 4 "(value)" Description Relative value set command. See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values." See section 7, "Parameter Values.
3. Command Specifications MRX7-D Command setr Option 1 MTX:Index_IndexNo Option 2 0 Option 3 Option 4 "(value)" 0 Description Relative value set command. Details: IndexNo = Index number assigned in Remote Control Setup List (value) = relative value to increase or decrease. (See "Fader Parameter" table in section 6 Parameter Value Details ) Note: This command is available only for fader type parameters.
3. Command Specifications 3.3.6. Meter control 2-17) Transmission request MTX3,MTX5-D,XMV,EXi8,EXo8 Command mtrstart Details: Option 1 Option 3 MTX:mtr_MemNo/UniqueId/meter (interval) MTX:mtr_MemNo/UniqueId/hold Description Requests that the specified meter data be transmitted. Requests that the specified hold meter data be transmitted. MemNo = See section 7, "Parameter Values." UniqueId = See section 7, "Parameter Values.
3. Command Specifications 2-18) Stop request MTX3,MTX5-D,XMV,EXi8,EXo8 Command mtrstop Details: Option 1 MTX:mtr_MemNo/UniqueId/meter MTX:mtr_MemNo/UniqueId/hold Description Requests that the specified meter data be stopped. Requests that the specified hold meter data be stopped. MemNo = See section 7, "Parameter Values." UniqueId = See section 7, "Parameter Values.
3. Command Specifications 3.3.7. Snapshot (preset) processing 2-19) Snapshot (preset) current number query processing Command Description Queries the current preset number (index) sscurrent Response Response string OK sscurrent (index) unmodified Description Current preset number queried (There is no parameter change after recalling.) Current preset number queried (There is a parameter change after recalling.
3. Command Specifications 3.4. Extended commands 3.4.1. Product information query request 3-1) MTX external control protocol version query Command Option 1 devinfo protocolver Description Queries the MTX external control protocol version Response Response string OK devinfo protocolver "xxxx" Details: Description MTX external control protocol version xxxx = Version Example: Command: Notification: Meaning: devinfo protocolver OK devinfo protocolver "1.0.0" Query the protocol version.
3. Command Specifications 3-5) Serial number query Command devinfo Option 1 serialno Description Queries the serial number Response Response string OK devinfo serialno "xxxx" Details: Description Serial number xxxx = Serial number Example: Command: Notification: Meaning: devinfo serialno OK devinfo serialno "ZA37640CHNET101001" Query the serial number.
3. Command Specifications 3.4.2. Snapshot (preset) list recall processing devinfo: queries the device status 3-8) Number of snapshot (preset) lists Command Description Queries the number of preset lists Response string Description The number of preset lists ssnum Response OK ssnum (num) Details: (num) = Quantity Example: Command: Notification: Meaning: ssnum OK ssnum 51 Query the number of presets. The number of presets is 51.
3. Command Specifications 3.4.3. Event processing request 3-10) Time synchronization Command Option 1 MTX:AbsoluteTime event Details: yyyy = mm = dd = hh = mm = ss = Option 2 "yyyy/mm/dd hh:mm:ss" Description Changes the time Year (Gregorian) Month (1 to 12) Day (1 to 31) Hour (0 to 23) Minute (0 to 59) Second (0 to 59) * DST (Daylight Saving Time) is not accounted for.
3.
3.
3.
3.
3. Command Specifications 3-27) Current folder information (for list) query Command event Option 1 MTX:AudioPlayerGetCurrentDir Option 2 "" Description Queries the current folder information. Response Response string OK event MTX:AudioPlayerGetCurrentDir "dirpath=xxxx|dirname=yyyy| subdirnum=zzzz|filenum=wwww" OKm event MTX:AudioPlayerGetCurrentDir "sdcard is not inserted" Description Current folder information There is no SD memory card inserted.
3. Command Specifications 3-30) File name query Command Option 1 MTX:AudioPlayerGetFileName event Details: Option 2 "fileindex=xxxx" Description File name query xxxx = Index number Response Response string OK event MTX:AudioPlayerGetFileName "filename=xxxx" OKm event MTX:AudioPlayerGetFileName "sdcard is not inserted" Description File name There is no SD memory card inserted. * OKm is returned if there is no SD memory card inserted.
3.
3.
3.
3.
3. Command Specifications 3-42) Query for alert event log as list Command event Details: Option 1 MTX:EventLogGetLogList Option 2 "logindex=xxxx-xxxx" Description Query for event log list xxxx-xxxx= First index number - Last index number Remark: Do not allow exceed number of event log. First index number should be less than Last index number. One message can query up to 10 logs.
3. Command Specifications 3.5. Command Errors 3.5.1. Command Error Notifications Error notification that indicates errors in commands. If an error is found when the command is sent, this notification is returned instead of the normal successful notification. [Notification syntax] Command name Error code ERROR Alphanumeric Alphanumeric Name of the command that caused the error Error description * See the error codes below.
4. Command Sequence Below are examples of how to process remote control. When viewed from the controller, the following major phases exist in order to perform remote control. Start procedure Communication start • Wait for the device to start (devstatus) Initial setting • MTX external control protocol setting (scpmode) • Parameter syncing (get, set, etc.) Normal procedure • Detect operation of controls. • Receive communication from the device. Detects the operation of controls by the user.
4. Command Sequence Communication start sequence The amount of time for the controller and the controlled device to start is different. Remote control is an act of controlling the controlled device from the controller, so the controller must wait for the controlled device to become ready. The controller needs to wait using the sequence below. 1. If an Ethernet connection is required, the remote controller needs to establish a logical session, with the MTX device(s) based on IP address(es) and port number.
4. Command Sequence Example when the controlled device starts earlier than the controller Remote controller Connected physically Starting Controlled device Device starting Device normal running Connection unknown devstatus runmode OK devstatus runmode "normal" Connection detection * With the first devstatus runmode request, a result notification is returned. Controller can recognize that Controlled device is ready to receive commands when there is response for "devstatus runmode" command.
4. Command Sequence Parameter sync sequence Immediately after communication starts, the controller does not know anything about the most recent status of the controlled device. Therefore, the controller must query all parameters that it plans to handle. This also applies for when preset recall is executed, because the controller does not know how the device has changed.
4. Command Sequence Applying the most recent status of the controller to the device Remote controller Controlled device Normally running Connection detection set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 Normally running Communication possible OK set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 "-77.
4. Command Sequence Meter data request/query sequence The controller requests meter data by specifying the meter data address and the minimum transmission interval. The meter transmission stops after 10 seconds. To continue receiving data, make another request before the 10 seconds pass. Remote controller Controlled device mtrstart MTX:mtr_512/20020/level 1000 OutputLevelMeter request Start measuring 10 seconds OK mtrstart MTX:mtr_512/20020/level NOTIFY mtr MTX:mtr_512/20020/level level 71 71 ...
4. Command Sequence Sequence when parameters are changed by another controller If the controller sends a parameter set request, a change notification is returned immediately. However, if parameters change internally in the controlled device (this includes changes in parameters that occur as a result of a controller operation on another parameter) or due to a request from another controller, a parameter change notification is received, as shown below.
5. Meter Value 1.
6. Parameter Value Details 6.1. Fader parameter 1. Fader with "-Infinity to 0dB"range Value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 Data -InfdB -138.00dB -136.00dB -134.00dB -133.00dB -132.00dB -131.00dB -130.00dB -129.00dB -128.00dB -127.00dB -126.00dB -125.00dB -124.00dB -123.00dB -122.00dB -121.00dB -120.00dB -119.00dB -118.00dB -117.00dB -116.00dB -115.00dB -114.
6. Parameter Value Details Value 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 Data -25.55dB -25.50dB -25.45dB -25.40dB -25.35dB -25.30dB -25.25dB -25.20dB -25.15dB -25.10dB -25.05dB -25.00dB -24.95dB -24.90dB -24.85dB -24.80dB -24.75dB -24.70dB -24.65dB -24.60dB -24.55dB -24.50dB -24.45dB -24.
6. Parameter Value Details 2. Fader with "-Infinity to 10dB"range Value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 Data -InfdB -138.00dB -135.00dB -132.00dB -129.00dB -126.00dB -123.00dB -120.00dB -117.00dB -114.00dB -111.00dB -108.00dB -105.00dB -102.00dB -99.00dB -96.00dB -95.00dB -94.00dB -93.00dB -92.00dB -91.00dB -90.00dB -89.00dB -88.00dB -87.00dB -86.00dB -85.
6. Parameter Value Details Value 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 Data -15.55dB -15.50dB -15.45dB -15.40dB -15.35dB -15.30dB -15.25dB -15.20dB -15.15dB -15.10dB -15.05dB -15.00dB -14.95dB -14.90dB -14.85dB -14.80dB -14.75dB -14.70dB -14.65dB -14.60dB -14.55dB -14.50dB -14.45dB -14.
6. Parameter Value Details ■■Other parameters (MTX3, MTX5-D) 1.
6. Parameter Value Details 2. 3 Band EQ / 4 Band EQ Q Value Displayed value Value Displayed value Value Displayed value Value Displayed value 0 0.1 29 0.53 58 2.8 87 15.0 1 0.105 30 0.56 59 3.0 88 16.0 2 0.11 31 0.6 60 3.2 89 17.0 3 0.12 32 0.63 61 3.3 90 18.0 4 0.125 33 0.67 62 3.5 91 19.0 5 0.13 34 0.7 63 3.8 92 20.0 6 0.14 35 0.75 64 4.0 93 21.0 7 0.15 36 0.8 65 4.2 94 22.0 8 0.16 37 0.85 66 4.5 95 24.0 9 0.17 38 0.9 67 4.7 96 25.0 10 0.18 39 0.95 68 5.0 97 27.0 11 0.19 40 1.0 69 5.3 98 28.0 12 0.2 41 1.
6. Parameter Value Details 3. Gate Decay Value Displayed value Value Displayed value Value Displayed value Value Displayed value 0 3msec 43 189msec 86 1.23sec 129 7.68sec 1 7msec 44 196msec 87 1.28sec 130 8.11sec 2 10msec 45 203msec 88 1.34sec 131 8.54sec 3 13msec 46 209msec 89 1.39sec 132 8.97sec 4 17msec 47 219msec 90 1.44sec 133 9.39sec 5 22msec 48 229msec 91 1.50sec 134 9.82sec 6 25msec 49 243msec 92 1.55sec 135 10.2sec 7 28msec 50 256msec 93 1.60sec 136 10.7sec 8 32msec 51 269msec 94 1.66sec 137 11.
6. Parameter Value Details Hold Value Displayed value Value Displayed value Value Displayed value Value Displayed value 0 0.02msec 54 2.01msec 108 20.2msec 162 211msec 1 0.04msec 55 2.10msec 109 20.9msec 163 222msec 2 0.07msec 56 2.19msec 110 21.6msec 164 233msec 3 0.09msec 57 2.28msec 111 22.6msec 165 245msec 4 0.11msec 58 2.36msec 112 23.6msec 166 256msec 5 0.14msec 59 2.45msec 113 25.0msec 167 267msec 6 0.16msec 60 2.54msec 114 26.4msec 168 278msec 7 0.18msec 61 2.62msec 115 27.8msec 169 289msec 8 0.
6. Parameter Value Details 4. Compressor Ratio Value Displayed value Value Displayed value Value Displayed value Value Displayed value 10 1.0:1 58 5.8:1 106 10.6:1 154 15.4:1 11 1.1:1 59 5.9:1 107 10.7:1 155 15.5:1 12 1.2:1 60 6.0:1 108 10.8:1 156 15.6:1 13 1.3:1 61 6.1:1 109 10.9:1 157 15.7:1 14 1.4:1 62 6.2:1 110 11.0:1 158 15.8:1 15 1.5:1 63 6.3:1 111 11.1:1 159 15.9:1 16 1.6:1 64 6.4:1 112 11.2:1 160 16.0:1 17 1.7:1 65 6.5:1 113 11.3:1 161 16.1:1 18 1.8:1 66 6.6:1 114 11.4:1 162 16.2:1 19 1.9:1 67 6.
6. Parameter Value Details 5. AGC Response Time Value Displayed value Value Displayed value 0 100msec 30 2.20sec 1 150msec 31 2.30sec 2 200msec 32 2.40sec 3 250msec 33 2.50sec 4 300msec 34 2.60sec 5 350msec 35 2.70sec 6 400msec 36 2.80sec 7 450msec 37 2.90sec 8 500msec 38 3.00sec 9 550msec 39 3.10sec 10 600msec 40 3.20sec 12 700msec 42 3.40sec 13 750msec 43 3.50sec 14 800msec 44 3.60sec 15 850msec 45 3.70sec 16 900msec 46 3.80sec 17 950msec 47 3.90sec 18 1.00sec 48 4.00sec 19 1.10sec 49 4.10sec 20 1.
6. Parameter Value Details 6. Effect Type Value 0 1 2 3 Displayed value Reverb Hall Reverb Stage1 Karaoke Echo Vocal Echo RevHallTime/RevStageTime Value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Time(sec) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 Value 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 KaraokeTime/VocalTime Time(sec) 3.2 3.3 3.4 3.5 3.6 3.7 3.
6. Parameter Value Details 7.
6. Parameter Value Details 8.
6. Parameter Value Details 9.
6. Parameter Value Details 11.
6. Parameter Value Details 12.
6. Parameter Value Details 13. MY4-AEC FBS Width Value 0 1 2 Depth Displayed value 1/10oct 1/60oct 1/93oct Value 0 1 2 Displayed value -6dB -12dB -18dB 14. MY4-AEC Digtal I/O SRC FsType Value 0 1 2 3 4 5 Displayed value 44.1kHz 48kHz 88.2kHz 96kHz AES/EBU IN CH1/2 AES/EBU IN CH3/4 MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.
6. Parameter Value Details ■■Other parameters (MRX7-D) 15. Ambient Noise Compensator Ratio Same as 8.Priority Processor ANC Ratio in "Other Parameters (MTX3,MTX5-D)" 16. Auto Gain Control Response Type Same as 8.Priority Processor AGC Response Time in "Other Parameters (MTX3,MTX5-D)" 17. PEQ Q Same as 2. 3Band EQ / 4Band EQ in "Other Parameters (MTX3,MTX5-D)" B/W(Q) Value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Oct. 6.672 6.534 6.403 6.158 6.044 5.934 5.728 5.537 5.
6. Parameter Value Details 18. Gate/Ducking Decay Same as 3. Gate in "Other Parameters (MTX3,MTX5-D)" Hold Same as 3. Gate in "Other Parameters (MTX3,MTX5-D)" Keyin(Mono) Value 0 1 Keyin(Stereo) Displayed value SELF KEYIN Value 2 3 4 5 Displayed value L R LR BOTH KEYIN 19. Paging Ducker Range Value -601 -600 -599 : : -2 -1 0 Displayed value -∞ -60.0dB -59.9dB : : -0.2dB -0.1dB -0.0dB 20.
6. Parameter Value Details KaraokeTime/VocalTime Value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 Time (sec) 0.4 3.2 6.4 9.5 12.7 15.8 19.0 22.1 25.3 28.4 31.6 34.7 37.9 41.0 44.2 47.3 50.5 53.6 56.8 59.9 63.1 66.2 69.4 72.5 75.7 78.8 82.0 85.1 88.3 91.4 94.6 97.7 100.9 104.0 107.2 110.3 113.5 116.6 119.8 122.9 126.1 129.2 132.4 135.5 138.6 141.8 144.9 148.1 151.2 154.4 157.5 160.
6. Parameter Value Details 21. Pitch Shift FBS Suppression Value 0 1 2 : : 8 9 Pitch (Cent) Speech Music -5 -2 -10 -4 -15 -6 : : : : -45 -18 -50 -20 22. Compressor Ratio Same as 4.Compressor in "Other Parameters (MTX3,MTX5-D)" Knee Same as 4.Compressor in "Other Parameters (MTX3,MTX5-D)" Release Same as 3.Gate in "Other Parameters (MTX3,MTX5-D)" Keyin(Mono) Same as 18.Gate/Ducking Keyin(Stereo) Same as 18.Gate/Ducking 23. HPF/LPF/BPF Filter Type Same as 7.
6. Parameter Value Details 25. Room Combiner plus Automixer Source Value 0 1 2 3 Displayed value BGM1 BGM2 BGM3 BGM4 26. Room Combiner Source Same as 22.Room Combiner plus Automixer above. 27. Oscillator Waveform Value 0 1 2 3 4 5 Displayed value SINE 100Hz SINE 1kHz SINE 10kHz Pink Burst VARI 28. Speech Privacy Select Type Value 0 1 2 3 Displayed value Forest Seashore Street Building 29. Speaker Processor HPF/LPF Type Same as 7.Speaker Processor in "Other Parameters (MTX3,MTX5-D)" PEQ Q Same as 7.
6. Parameter List 7.
Model Access ID MemNo ElmNo Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (X Position) (Y Position) Number) Number) o 512 40002 0 0-7 0 (1-8ch) o 40000 40001 0-7 o (9-16ch) o 40002 0 0-7 0 (1-8ch) o 40000 o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o 40001 40002 0 40000 40001 40002 0 40000 40001 40002 0 40000 40001 40002 1 40000 40001 40000 0 40002 40003 40000 0 40002 40003 40000 0 40002 40003 40000 0 40002 40003 40000 0 40002 40003 40000 0 40002 40003 40000 1 40002 40003 40005 0
7. Parameter List Model Access ID MemNo ElmNo Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (X Position) (Y Position) Number) Number) 512 40005 3 0-3 0-6 o (1-4ch) (Freq1-7) 40004 0-7 o (1-8ch) 40004 0 0-3 0 o (1-4ch) 40005 0-7 o (1-8ch) 40004 0-3 o (1-4ch) 40005 0-7 o (1-8ch) 40004 0-3 o (1-4ch) 40005 0-7 o (1-8ch) 40004 1 0-3 0 o (1-4ch) 40005 0-7 o (1-8ch) 60000 0 0-7 0 (1-8ch) o Feedback Fixed Suppressor Filter 4(8) Channel AGC AutoGainControl Compensator Response 100m 5.
7. Parameter List Model Access ID MemNo ElmNo Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (X Position) (Y Position) Number) Number) o 512 40001 0 0-3 0 (STIN1Lo 40006 2R) 40001 0 0 o o o o o o o o o Attack 0 120 0 4 0 Release 3.2m 42.600 s 0 5 0 Gain 0.0 18.0 dB 0 0 0 On OFF ON - 0:OFF 1:ON 0 0 AutoGainControl Compensator Response 100m 5.0 4 Channel Time s * See "5.AGC" in "6.
7. Parameter List Model Access ID MemNo ElmNo PrmNo IndexNo Category Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (Parameter (Index (X Position) (Y Position) Number) Number) Number) Number) 512 20006 0 0-1 0 1 0 EFFECT o (Effect1-2) 20013 o 20006 1 o o o o o 20014 o 20008 1 20014 70004 0 o o o 60000 1 o o 2 o 0-3 0 (Fx.RTN1L - 2R) 0.3 10.0 s 1 Rev 0.3 Stage Time 10.0 s 2 Karaoke 0.4 Time 400 ms 3 Vocal 0.
7.
7. Parameter List Model Access ID MemNo ElmNo Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (X Position) (Y Position) Number) Number) 512 20011 0 0 0-7 (0:ZONE1 2nd o PRIORITY PRIORITY SOURCE : 20018 7:ZONE8 2nd o PRIORITY PRIORITY SOURCE) o 20012 0 0-7 0 (ZONE1-8) o 20019 o 20012 o 20019 o 20012 o 20019 20012 o o o o o o 20012 20019 20011 0 o o o o o 0 20013 0 20020 20013 20020 20013 20020 20013 0-7 (ZONE1-8) o o o o dB Range -70 0 dB 2 Attack 0 240 ms 3 Release 3.2m 42.
7. Parameter List Model Access ID MemNo ElmNo PrmNo IndexNo Category Xpos Ypos MTX3 MTX5-D (Memory UniqueId (Element (Parameter (Index (X Position) (Y Position) Number) Number) Number) Number) 512 20014 0 0-7 0 0 0 ZONE ZONE OUT ANC (ZONE1-8) 1-8(16) o o o o o o o o o o o o 20014 20021 20014 3 20021 60002 0 o 70001 0 70005 60002 1 o 0.00 dB dB x 100 ex.-73.60dB x 100 = -7360 "setr" command is available for this parameter 1 Time 0.1 5.0 s sec x 10 ex. 3.
7.
7.
7.
7.
7.
7.
7.
7.
7. Parameter List MRX7-D Parameter Name Ch ANALOG IN ANALOG OUT Gain +48V -6 OFF 66 ON unit dB - Polarity NORMAL INVERTED - Gain -96.0 24.0 dB Polarity NORMAL INVERTED - Gain -96.0 24.0 dB Polarity NORMAL INVERTED - Gain -96.0 24.0 dB AEC ON OFF ON - NR ON OFF ON - Ambient Threshold Threshold -72 -∞ -25 0.00 dB dB Gap Threshold -∞ 0.00 dB Time 0.1 5.0 s MaxGain 0.0 18.0 dB MinGain -18.0 0.0 dB Ratio* 0.5:1 2.
7. Parameter List Combiner Parameter Name Room Combiner plus Master Automixer MAX unit OFF ON - Mute OFF ON - ON OFF ON - Level -∞ 10.00 dB Source* BGM1 BGM4 - ON OFF ON - Level -∞ 10.00 dB ON OFF ON - Level -∞ 10.00 dB ON OFF ON - Level -∞ 10.00 dB ON OFF ON - Level -∞ 10.00 dB Combine ON OFF ON - MicCh Mode* Mute Auto - Weight Override -100.0 OFF 15.0 ON - Override OFF ON - Mute OFF ON - ON OFF ON - DelayTime 0.00 50.
7. Parameter List Dynamics Parameter Name Compressor Dyn Ducking Gate Limiter Paging Ducker Effect Threshold Ratio* -54 1.0:1 MIN 0 ∞:1 MAX unit dB - Knee* HARD 5 - Attack Release* 0 3m 120 42.7 ms s Gain 0.0 18.0 dB KeyIn KeyIn* SELF KEYIN - On ON OFF ON - Dyn Threshold Range Attack Release* -54 -70 0 3m 0 0 240 42.7 dB s Hold* 0.02m 1.96 s KeyIn KeyIn* SELF KEYIN - On ON OFF ON - Dyn Threshold Range Attack Decay* -72 -70 0 3m 0 0 120 42.
7. Parameter List EQ GEQ Parameter Name Property Limit ±15 -24 unit dB GEQOn OFF ON - Frequency 20.0 20.0k Hz Bypass OFF ON - Frequency 20.0 20.0k Hz Bypass OFF ON - Frequency 20.0 20.0k Hz Bypass OFF ON - GEQ Q* Gain Bypass 63.0 -24.0 OFF 0.1 15.0 ON dB - PEQ Q* 63.0 0.1 - Frequency 20.0* 20.0k Hz Gain* Bypass -18.0 OFF 18.0 ON dB - Property Type PEQOn PEQ OFF LPF ON - Fader Level -∞ 10.
7. Parameter List Mixer Parameter Name Dugan Automixer Master Ch Delay Matrix Ch MIN MAX unit Override OFF ON - Mute OFF ON - Mode* Mute Auto - Weight Group* -100.0 a Override OFF 15.0 dB b (2 - 4 Channel) d (5 - 8 Channel) h (9 - 16 Channel) ON - Level -∞ 0.00 dB On OFF ON - DelayTime 0.00 250.00 ms 500.00 Matrix Mixer Oscillator Mono Ch Oscillator Polarity Level -∞ 0.00 dB ON OFF ON - Level -∞ 0.0 dB ON OFF ON - VariFrequency 20.0 20.
7. Parameter List Speaker Processor Parameter Name In Level -∞ 10.00 unit dB ON OFF ON - Delay 0.00 500.00 ms LPFFrequency 20.0 20.0k Hz HPFFrequency 20.0 20.0k Hz LPFType Thru - HPFType Thru LPFGc* HPFGc* Polarity -6 -6 NORMAL 48dB/Oct Linkwitz 48dB/Oct Linkwitz 6 6 INVERTED Center Frequency 20.0 20.0k Hz PEQ Q* 63.0 0.1 - Frequency 20.0* 20.0k Hz Gain* -18.0 18.0 dB Bypass OFF ON - Type PEQ Horn EQ - Threshold Attack -54 0.0 0 120.
7.
7. Parameter List EXi8 Access ID MemNo ElmNo PrmNo IndexNo Xpos Ypos (Memory UniqueId (Element (Parameter (Index (X Position) (Y Position) Number) Number) Number) Number) 512 1 3 0 to 7 0 0 0 1 Parameter Name MIN Signal GAIN Processing +48V MAX unit -6 OFF 66 ON dB - 2 Phase OFF ON - 3 On OFF ON - 4 HPFOn OFF ON - 5 HPFFrequency 20 20000 Hz MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.
7. Parameter List EXo8 Access ID MemNo ElmNo PrmNo IndexNo Xpos Ypos (Memory UniqueId (Element (Parameter (Index (X Position) (Y Position) Number) Number) Number) Number) 512 1 3 0 to 7 0 0 0 1 2 Parameter Name Signal Polarity Processing On Gain MIN MAX unit Normal Inverse - OFF ON - -96 24 dB MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.0 rev8 Remarks 0:Normal 1:Inverse 0:OFF 1:ON dB x 10 ex. -14.
7.
8.
8.
8. Meter List Model MTX3 o Access ID MemNo Category MTX5-D (Memory UniqueId Number) 512 OUTPUT CHANNEL 20020 o o o OUTPUT PORT OUTPUT (ANALOG) 20031 20032 90000 o OUTPUT CHANNEL 20027 20025 o Meter Name OUTPUT (SLOT) MY4-AEC Meter 8 Channel (OUTPUT CH1-8) Meter 16 Channel (OUTPUT CH1-16) Meter 8 Channel (OUTPUT CH1-8) Meter 8 Channel (OUTPUT CH1-8) Meter 16 Channel (SLOT OUT 1-16) MY4-AEC (Mic In. 1-4 Ref In. 1-4 Echo Attn. 1-4 ERL 1-4 PTT Thesh.
8. Meter List MRX7-D Category - - - - - - - - Meter Name 8 Channel (INPUT1-8) ANALOG OUT 8 Channel (OUTPUT1-8) YDIF IN 16 Channel (YDIF IN 1-16) SLOT IN 16 Channel (SLOT IN 1-16) SLOT OUT 16 Channel (SLOT OUT 1-16) STEREO IN 4 Channel (INPUT 1L-INPUT 2R) MY4-AEC 16 Channel (MicIn.1-4 RefIn.1-4 EchoAttn.1-4 ERL.
8.
8. Meter List *1 Room Combiner plus Auto Mixer No.
8. Meter List *2 Dugan Automixer 2 - 4 Channel No.
8. Meter List *3 Dugan Automixer 5 - 8 Channel No.
8.
8. Meter List XMV Series Model 4ch 8ch o 4ch D 8ch D o o o Category Meter Name INPUT o 20001 o o Access ID MemNo (Memory UniqueId Number) 512 20000 - o - OUTPUT Meter 4 Channel (ANALOG INPUT A-D, DIGITAL INPUT A-D) Meter 8 Channel (ANALOG INPUT A-H, DIGITAL INPUT A-H) Meter 4 Channel (OUTPUT A-D) Meter 8 Channel (OUTPUT A-H) Type level Remarks See 6. Parameter Value Details. level level level MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.
8. Meter List EXi8 Access ID MemNo UniqueId (Memory Number) 512 20000 Category - Meter Name INPUT Meter 8 Channel (INPUT1-8) Type level Remarks See Parameter Value Details. MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.
8. Meter List EXo8 Access ID MemNo UniqueId (Memory Number) 512 20001 Category - Meter Name OUTPUT Meter 8 Channel (OUTPUT1-8) Type level Remarks See Parameter Value Details. MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V2.2.