Operation Manual
8
Be sure to switch the position only when the power to this unit is
not on.
Select the position whose requirements your speaker system
meets.
(Left position)
If you use one pair of speakers, the impedance of each
speaker must be 4Ω or higher.
If you use two pairs of speakers, the impedance of each
speaker must be 8Ω or higher.
(Right position)
<For U.S.A. model only>
If you use one pair of speakers, the impedance of each
speaker must be 6Ω or higher.
If you use two pairs of speakers, the impedance of each
speaker must be 12Ω or higher.
<For Canada model only>
The impedance of each speaker must be 6Ω or higher.
<Except U.S.A. and Canada models>
If you use one pair of speakers, the impedance of each
speaker must be 8Ω or higher.
If you use two pairs of speakers, the impedance of each
speaker must be 16Ω or higher.
IMPEDANCE SELECTOR switch
A OR B
:4
Ω
MIN. /SPEAKER
A B
:8
Ω
MIN. /SPEAKER
A OR B
:6
Ω
MIN. /SPEAKER
A B
:I2
Ω
MIN. /SPEAKER
IMPEDANCE SELECTOR
SET BEFORE POWER ON
A
WARNING
Do not change the IMPEDANCE SELECTOR switch
setting while the power to this unit is on, otherwise
this unit may be damaged.
IF THIS UNIT FAILS TO TURN ON WHEN THE
STANDBY/ON SWITCH IS PRESSED;
The IMPEDANCE SELECTOR switch may not be set to
either end. If so, set the switch to either end when this unit
is in the standby mode.
IMPEDANCE SELECTOR
For Custom Installer
For U.S.A., Canada and Australia models only
REMOTE CONTROL (IN, OUT) terminals
These terminals are used for custom installation system.
When this unit is connected to the components for custom
installation system, you can operate this unit with the
system remote control.
Connect the REMOTE CONTROL IN terminal of this unit to
the output terminal of the central controller for custom
installation system.
By connecting the REMOTE CONTROL OUT terminal of
this unit to the REMOTE CONTROL IN terminal of the other
component, you can also operate the component with the
system remote control. In this way, up to 6 components can
be connected in series.
GND REMOTE CONTROL
PLAY REC
PHONO
CD
IN OUT
TAPE 1
/MD
PLAY REC
TAPE 2
1
3
4
3
5
AUX
AUDIO SIGNAL
or
4 6
or
(U.S.A. model)