User Manual

Table Of Contents
Setup
V5.8 Reference Manual
255
NOTE
In Surround mode, you cannot use cascade output on MIX buses1-6. In addition, if you have
selected 5.1 SOLO in CUE mode, you cannot monitor CUE from the cascade follower at the
cascade leader.
If you are making a cascade connection between the CL unit and the PM5D, you can use the CL
unit as the cascade follower by setting the PM5D’s CASCADE IN PORT SELECT to a slot.
However, only the audio signals will be cascaded, and the control signals cannot be linked.
You can also use an AD/DA card to make cascade connections with an analog mixer.
There is no limit to the number of units that can be cascade-connected, but the signal delay at
the cascade follower will increase in accordance with the number of units from the cascade
leader.
Operations on a cascade follower CL unit
NOTE
You cannot assign two or more buses to the same output port. If you select a port to which a
signal route has already been assigned, the previous assignment will be canceled.
Control signals for the cascade link and MIDI messages cannot share the same port. If you select
a port that is already specified for transmission/reception of MIDI messages, a dialog box will ask
whether it is OK to cancel the existing settings.
CASCADE window (CASCADE OUT PATCH page)
You can select the slot and output port that will output each bus.
1 OUT PATCH buttons (CASCADE OUT PATCH section)
Enable you to select the output port for cascade connections for each of MIX 1-24,
MATRIX 1-8, STEREO L/R, MONO, and CUE L/R buses. Press the button to open the
PORT SELECT window, in which you can select a port.
2 CASCADE LINK buttons
Used to select the operations to be linked when making cascade connections between
CL series consoles. Multiple selection is possible.
•DCA 1-8
The following parameters related to DCA 1 to 8 will be linked.
DCA 1 - 8 level
DCA 1 - 8 on/off
DCA 1 - 8 cue
DCA 1 - 8 DCA MUTE TARGET (DCA group mute targets)
NOTE
Even if the cue mode is LAST CUE, the cue for the target DCA will come on at the same time
for consoles linked by cascade connections.
•DCA 9-16
The following parameters related to DCA 9 to 16 will be linked.
•DCA 9 - 16 level
DCA 9 - 16 on/off
STEP
1. In the Function Access Area, press the SETUP button.
2. In the SYSTEM SETUP field of the SETUP screen, press the CASCADE button.
3. In the CASCADE window, press the CASCADE OUT PATCH tab.
4. In the CASCADE OUT PATCH page, press the OUT PATCH button for the bus to which
you want to assign the port.
5. Use the slot select list and the port select buttons to select the slot and output ports
that you want to assign, and then press the CLOSE button.
6. In the CASCADE COMM PORT field, select the port that will transmit and receive
control signals for cascade link.
7. Use the CASCADE LINK MODE buttons to select the item that you want to link.
3
1
2
4