[210]: Bind Head Tapping Screw-B 3.0X6 MFZN2BL (EP600230)
[211]: Bind Head Tapping Screw-B 3.0X8 MFZN2BL (EP600190)
[212]: Bonding Head Screw-B 3.0X10 MFZN2BL (VQ498000)
4. PN Circuit Board
4-1 Remove the bottom case assembly. (See Proce-
dure 1.)
4-2 Remove the DM circuit board. (See Procedure 2.)
4-3 Remove the FDD assembly. (See Procedure 3.)
4-4 Remove the four (4) screws marked [210], the two
(2) screws marked [212] and the four (4) screws
marked [211]. The shield cover can then be re-
moved. (Fig. 3)
4-5 Remove the four (4) knobs marked [320]. (Fig. 4)
4-6 Remove the twelve (12) screws marked [60]. The
PN circuit board can then be removed. (Fig. 5)
[60]: Bind Head Tapping Screw-B 3.0X6 MFZN2BL (EP600230)
(Fig.5)(Fig. 4)
(Fig.3)
[330]: Knob (V2887900)
[320]: Knob (V2647700)
Rear View