No. Case Action Address Meter Type
Parameter
Value min max default
32 Request noise gate signal GR meter level
notification stop for mic input CH
mtrstop RM:ExtMicGateGR - - - - - -
33 Noise gate signal GR meter data for mic input
CH
NOTIFY mtr RM:ExtMicGateGR gr 0x00 - 0x7F meter level.
(x Channel)
See data table
(GR Meter)
0x00
34 Request compressor signal level notification
start for mic input CH
mtrstart RM:ExtMicCompOut - 1 - 10000 meter transmittion
interval
1 10000 40
35 Request compressor signal level notification
stop for mic input CH
mtrstop RM:ExtMicCompOut - - - - - -
36 Compressor signal level meter data for mic
input CH
NOTIFY mtr RM:ExtMicCompOut level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
37 Request compressor signal GR meter level
notification start for mic input CH
mtrstart RM:ExtMicCompGR - 1 - 10000 meter transmittion
interval
1 10000 40
38 Request compressor signal GR meter level
notification stop for mic input CH
mtrstop RM:ExtMicCompGR - - - - - -
39 Compressor signal GR meter data for mic input
CH
NOTIFY mtr RM:ExtMicCompGR gr 0x00 - 0x7F meter level.
(x Channel)
See data table
(GR Meter)
0x00
40 Request AGC RMS level notification start for
mic input CH
mtrstart RM:ExtMicAGCIn - 1 - 10000 meter transmittion
interval
1 10000 40
41 Request AGC RMS level notification stop for
mic input CH
mtrstop RM:ExtMicAGCIn - - - - - -
42 AGC RMS level meter data for mic input CH NOTIFY mtr RM:ExtMicAGCIn level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
43 Request automix gain level notification start for
NearEnd input CH
mtrstart RM:NeInAutomixGain - 1 - 10000 meter transmittion
interval
1 10000 40
44 Request automix gain level notification stop for
NearEnd input CH
mtrstop RM:NeInAutomixGain - - - - - -
45 Automix gain level meter data for NearEnd
input CH
NOTIFY mtr RM:NeInAutomixGain level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
46 Request automix out level notification start for
NearEnd input CH
mtrstart RM:NeInAutomixOut - 1 - 10000 meter transmittion
interval
1 10000 40
47 Request automix out level notification stop for
NearEnd input CH
mtrstop RM:NeInAutomixOut - - - - - -
48 Automix out level meter data for NearEnd input
CH
NOTIFY mtr RM:NeInAutomixOut level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
49 Request AGC RMS level notification start for
NearEnd input CH
mtrstart RM:NeInAGCIn - 1 - 10000 meter transmittion
interval
1 10000 40
50 Request AGC RMS level notification stop for
NearEnd input CH
mtrstop RM:NeInAGCIn - - - - - -
51 AGC RMS level meter data for NearEnd input
CH
NOTIFY mtr RM:NeInAGCIn level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)