V1.7 Supplementary Manual This supplementary manual explains mainly the functions that have been added or changed in CL5/CL3/CL1 firmware V1.6 and V1.7. Use it in conjunction with the CL5/CL3/CL1 Owner’s Manual and Reference Manual.
Contents Contents User settings............................................................................ 15 Added functions for the GAIN/PAN/ASSIGN knobs (assignable encoders)............... Added custom fader bank functions ....................................................................... Added load/save functions ..................................................................................... Added function for recovering from USB overcurrent..............................................
SELECTED CHANNEL section ■ D.GAIN indication SELECTED CHANNEL section Improved gain indication In the GAIN/PATCH field of the SELECTED CHANNEL VIEW screen, the analog gain and digital gain of the head amp are both shown at all times. ■ A.GAIN indication • Gain value If digital gain is assigned to the GAIN knob, the analog gain value is shown here. OVER indicator Ø (Phase) indicator The analog gain value is not shown if an input without a head amp is patched to the input channel.
Centralogic section Centralogic section Improved HPF indication The HPF status of an external head amp such as the R-series is now shown in the GAIN/PATCH field of the SELECTED CHANNEL VIEW screen. Improved DCA group indication If 15 or more channels are registered in the DCA member indication of the OVERVIEW screen, you can now use the multifunction knobs of the Centralogic section to scroll the channels. • HPF ON indicator Indicates the HPF on/off status of the external head amp.
Input channels ■ Settings in the PORT SELECT popup window Input channels Additional head amp setting functions when changing the input patching 1. In the OVERVIEW screen, press the GAIN/PATCH field to access the GAIN/PATCH popup window. 2. Press the PATCH button (or INPUT PORT button) to access the PORT SELECT popup window.
Input channels If the channel’s HA settings are selected, the following HA settings will be copied from the channel to the port that is patched. If you patch the input channel from an input that does not have these settings (i.e., that does not have a HA), the default values will be specified.
Grouping and linking Grouping and linking 3. Press the NAME EDIT button to access the NAME screen. The keyboard window will appear, allowing you to enter or edit the text. 4. The DCA group name is shown on the DCA group select button. Improved display of DCA group / MUTE group names In the DCA/MUTE GROUP ASSIGN MODE popup window, the DCA group names and mute group names can now be displayed. ■ Editing and displaying DCA group names 1. In the Function Access Area, press the CH JOB button. 2.
Grouping and linking ■ Editing and displaying mute group names Mute group names can be specified in the same way as for DCA groups. Added functions for DCA groups Sends from an input channel to a bus whose send point is set to PRE can now be assigned to be muted by a DCA group. 1 1 NAME EDIT button Edits the group name of the currently selected MUTE group.
Grouping and linking Improvements in channel link display A link indicator has been added to the CH LINK MODE popup window, making it easier to determine the currently-assigned link group. ■ Accessing the CH LINK MODE popup window 1. In the Function Access Area, press the CH JOB button. 2. Press the CH LINK button to open the CH LINK MODE popup window. Link indicator 3.
Monitor and Cue Monitor and Cue Meters Extended cue functions Added functions for meter display The cue monitor level range has been expanded to –30 dB – +20 dB. PRE GC METER and POST DIGITAL GAIN METER have been added to the METERING POINT field of the METER screen. In addition, the name of PRE HPF has been changed to PRE D.GAIN. Make this setting in the CUE popup window. ■ Accessing the CUE popup window 1. In the Function Access Area, press the MONITOR button to access the MONITOR screen. 2.
Graphic EQ, Effects, and Premium Rack MIX 1 2 2324 M O N O MATRIX L R (C) 1 2 7 8 ST Graphic EQ, Effects, and Premium Rack CUE L R CH 1-72{64,48} To RACKIN PATCH To OUTPUT PATCH INSERT POINT POST ON INSERT OUT PRE FADER INSERT OUT PRE EQ INSERT OUT CH INSERT OUT 1-72{64,48} CH INSERT IN 1-72{64,48} PRE D.
I/O device and external head amp I/O device and external head amp R-series The Rio field of the I/O DEVICE screen shows indicators for the status of the R-series units and the Dante network. Added display functions for device status You can now use the touch screen to verify the status of a connected CL series or R-series unit (except the Ro8-D) or the Dante status. In order to verify the status of an R-series unit from the console, it must be assigned to REMOTE HA in DANTE SETUP.
I/O device and external head amp Messages SYSTEM Indicators Error, warning, and information messages are displayed. Messages are also displayed in the Dante Controller Error Status field. Each indicator lights or flashes as described below: No call-out The indicator is off. Light The indicator remains lit steadily. Flash The indicator continues to flash. Flash x2 The indicator flashes twice cyclically. Flash x3 The indicator flashes three times cyclically.
I/O device and external head amp Improvements in I/O device settings If the green indicator is flashing, the unit is the clock master. If the green indicator is lit, the unit is the clock slave and the clock is synchronized. SYNC Indicators Light or flash Description When mounting an I/O device on the Dante audio network, the settings and indications have been improved so that the units can be differentiated by their device type. Possible Solution A non-GbE-compatible device is connected.
User settings User settings Added custom fader bank functions Custom fader bank settings can now be stored/recalled for individual scenes. Custom fader bank settings are separated into areas for each model and stored together in the scene data. Added functions for the GAIN/PAN/ASSIGN knobs (assignable encoders) Custom fader bank settings Functions have been added to the assignable encoders in SENDS ON FADER mode.
User settings ■ Focus function For the focus function, you can specify for each scene whether custom bank settings will be recalled (loaded). 1. Press the SCENE field of the Function Access Area. 2. Press the FOCUS tab at the bottom of the SCENE LIST window. 4. Press a button in the FOCUS PARAMETER field to access the FOCUS PARAMETER popup window. 5. Verify the object of focus. 6. Press the CLOSE button to close the popup window; then perform a recall operation.
User settings ■ Recall Safe function In the Recall Safe function, you can specify that custom bank settings of all scenes will be globally excluded from recall operations. ■ Global Paste function The global paste function lets you copy and paste the custom bank settings of the current scene to scene data in memory. 1. In the Function Access Area, press the CH JOB button to access the CH JOB popup window. 1. In the Function Access Area, press the SCENE field to access the SCENE LIST window. 2.
User settings Added load/save functions 3 DESTINATION field CL series settings can now be loaded individually from a USB flash drive, or saved individually to a USB flash drive. 4 Data selection knob Indicates the load-destination. This knob selects the data shown in the field. Loading settings from a USB flash drive 5 MULTI SELECT button By pressing this button you can make a selection containing multiple items of data.
User settings Buttons Saving the CL console’s settings on a USB flash drive Data content Opt-2A LIB Opt-2A library EQ-1A LIB EQ-1A library DynaEQ LIB DynamicEQ library Here’s how to save the CL console’s internal data on a USB flash drive. • SETUP tab The following table lists the items that you can select. Buttons 1. In the Function Access Area, press the SETUP button to access the SETUP screen. 2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window. 3.
User settings 6 SELECT ALL button • SETUP tab The following table lists the items that you can select. Press this button to select all items. Buttons 7 CLEAR ALL button MIXER SETUP Press this button to clear all selections. 5. Press the tabs and buttons of the TYPE field to select the type of data that you want to save. The content shown in the TYPE field will vary depending on the tab you select. • ALL tab All items will be the target of the operation.
User settings Added function for recovering from USB overcurrent Even if the connection with the USB device was stopped because an overcurrent condition occurred at the USB port, it is now possible to reconnect the USB device without restarting. Recovery procedure After removing the cause of the overcurrent at the USB port, press the location that shows “USB REMOUNT” at the FORMAT button of the SAVE/LOAD screen. 21 V1.
Other functions Other functions Added channel color Improvements to the channel name display Black can now be specified as a channel color. If black is selected for a channel, its channel color indicator will be unlit. Improvements have been made to the channel name display and channel color indicator. Make this setting in the CH COLOR/ICON popup window. ■ Channel color setting The channel on/off status is now shown in SENDS ON FADER mode. 1.
Other functions Added GPI functions Initializing the Dante audio network settings You can now select the attributes (latched or unlatched) of an external switch connected to a GPI IN port. It is now possible for Dante-related settings to also be initialized to their factory-set state when an error occurs on the Dante audio network. NOTICE ■ GPI settings When you initialize, all console settings including the Dante audio network settings that had been previously saved in memory will be lost. 1.
Block Diagram MIX 1 2 2324 M O N O MATRIX L R (C) 1 2 7 8 ST CUE L R CASCADE OUT MIX CASCADE OUT1-24 To OUTPUT PATCH To OUTPUT PATCH CASCADE IN To OUTPUT PATCH To OUTPUT PATCH STEREO CASCADE OUT L,R,MONO(C) SLOT1 1-16 SLOT2 1-16 SLOT3 1-16 CASCADE IN SELECT +48V MASTER +48V MATRIX CASCADE OUT1-8 CUE CASCADE OUT LR HA 2 TALKBACK INPUT METER + - 1 3 1 DANTE INPUT To OUTPUT PATCH ON INPUT SELECT OSCILLATOR Sine Wave Pink Noise Burst Noise INPUT PATCH 64 To RACKIN PATCH To OUTPUT PAT
CUE / MONITOR MONITOR DELAY AUTO BYPASS CUE TRIM (INPUT/OUTPUT/DCA) CUE L BUS CUE L CUE R BUS CUE R CUE ON MONO CUE OUT ON METER CUE L METER CUE R DELAY (MAX:1000ms) DELAY (MAX:1000ms) CUE OUT L To OUTPUT PATCH CUE OUT R To OUTPUT PATCH CUE OUT LEVEL CUE LOGIC DEFINE MIX (MAX:8ch) MONITOR L MONO METER MONITOR L MONITOR R METER MONITOR R MONITOR MONO(C) METER MONITOR MONO(C) ON ON MONITOR OUT MONO(C) DELAY (MAX:1000ms) +MONO(C) To PHONES OUT To PHONES OUT MONITOR OUT R DELAY (MAX
Yamaha Pro Audio Global Web Site http://www.yamahaproaudio.com/ Yamaha Manual Library http://www.yamaha.co.jp/manual/ C.S.G.