User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Setup
V5 Reference Manual
230
5 MULTI SELECT button
Press this button to make a selection containing multiple items of data.
6 SELECT ALL button
Press this button to select all items.
7 CLEAR ALL button
Press this button to clear all selections.
NOTE
• To select a different directory as a save destination, in the SAVE/LOAD window, press a directory
icon or press the arrow button in the PATH field.
• If you are going to overwrite a file or save a file with the same name in the same folder, a dialog
will ask you to confirm the overwrite.
• You can enter a comment of up to 32 characters.
• You may enter a file name of more than eight characters. However, the drive name, path name,
and file name are limited to a total of 256 characters. If you exceed this limit, you may be unable
to save the file, depending on the length of the file name. If this error indication appears at the
bottom of the screen, shorten the file name and try saving the file again.
Loading a file from a USB flash drive
Follow the steps below to load a QL settings file (extension .CLF) from the USB flash drive
into the QL series console.
You can use the same procedure to load the following files as well as settings files.
NOTICE
Some data may contain settings that will cause the console to output signals immediately after
the data is loaded. Before you load, turn off the power of the equipment connected to the QL
series console and/or lower the volume of such equipment so that there will not be a problem
even if a signal is output from the QL console.
NOTE
• When the file has finished being loaded, the window that shows the progress of the loading
operation and the type of data will close. If you cancel this procedure while it is in progress, data
up to the cancellation point will still be loaded.
• Some setting data may not be loaded, depending on the USER LEVEL setting during the load
operation.
Extension Type Contents of file
.CLF ALL QL console internal setting file
.CLU KEY QL console user authentication key
.XML XML XML file for displaying Help
.TXT TEXT Text file for displaying Help
.BMP BMP
Image file for display in the CONSOLE LOCK screen (256 or more
colors, uncompressed bitmap format)
STEP
1. To select the file that you want to load, press the name of the desired file in the file
list in the SAVE/LOAD window, or rotate the [TOUCH AND TURN] knob.
2. If you want the DANTE SETUP and I/O device-related settings saved in the QL
settings file (file name extension .CLF) and the word clock settings to be applied to
the QL console, press the WITH DANTE SETUP AND I/O DEVICE button to turn it on.
3. In the SAVE/LOAD window, press the LOAD button.
4. In the LOAD SELECT screen, select the data to load, the data type, and the load
destination.
5. Press the LOAD button to load the selected file.