User Manual
Table Of Contents
- Introduction
- Audio Components
- The Difference Between Mono, Stereo, and Multi
- How to Control Control Signals
- Acoustic Echo Canceller (AEC)
- Ambient Noise Compensator (ANC)
- Audio Detector
- Auto Gain Control (AGC)
- Combiner
- Room Combiner/Room Combiner plus Automixer
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- Combiner parameter setting window (Room Combiner)
- Combiner parameter setting window (Room Combiner plus Automixer)
- Control
- Control
- Dugan Automixer window (Room Combiner plus Automixer)
- Room Combiner/Room Combiner plus Automixer
- DCA
- Delay
- Dynamics
- REV-X
- EQ
- Fader
- Feedback Suppressor
- Filter
- Input/Output
- Meter
- Mixer
- Oscillator
- Polarity
- Probe
- Router
- Source Selector
- Speaker Processor
- Control Components
- Control Methods for Control Components
- Trigger
- Button (Normalized Value)
- Button (Value)
- Radio Button (Normalized Value)
- Radio Button (Value)
- Fader (Normalized Value)
- Fader (Value)
- Processing
- Logic (Normalized Value)
- NOT (Normalized Value)
- Flip-Flop (Normalized Value)
- Invert (Normalized Value)
- Compare (Normalized Value)
- Difference (Normalized Value)
- Max/Min (Normalized Value)
- Negate (Value)
- Compare (Value)
- Multi Compare (Value)
- Difference (Value)
- Max/Min (Value)
- Delay
- External Events
- Suspend
- Router
- Other
- GPI In
- GPI Out
ProVisionaire Design DME7 Component Guide
151
Max/Min (Value)
This component detects and outputs the largest/smallest value of the values input from
multiple ports.
(For 2 inputs)
INPUT
1: Input value 1 (–20,000 to 20,000), (−∞ to 10.00)
2: Input value 2 (–20,000 to 20,000), (−∞ to 10.00)
OUTPUT
Max: The largest value from multiple input values
Min: The smallest value from multiple input values
■ ”Max/Min” component editor
① The input value (0.00–1.00) can be checked.
② The largest value among all channel inputs is displayed as Max and output from the Max
port.
The smallest value among all channel inputs is displayed as Min and output from the Min
port.
Parameter types of the input/output values for each Port
Input Value Operation Output Value
Type Range Input Port Name
Trigger/
Processing
Output Port Name Type Range
Value
Num -20000–20000
●
CH (1,2..)
Processing:
Max/Min
- - - -
dB −∞–10.00
- - - -
- - -
-
●
Max Value
Num OFF:0, ON:1
dB −∞–10.00
- - -
-
●
Min Value
Num OFF:0, ON:1
dB −∞–10.00