User Manual
Table Of Contents
- Cover
- What is Amp Editor?
- Special Notices
- Contents
- Preparing for operation
- An overview of Amp Editor
- Setup
- Basic operations in Amp Editor
- Main panel window
- Objects in the window and their function
- Menus in the main panel window
- Preferences
- Event Log
- Device Information
- Scene Manager
- Alert Setup
- Word Clock (TXn only)
- Speaker Processor Library Manager (TXn only)
- Clock
- Language (TXn only)
- GPI (ACD1 only)
- Utility
- IP Address
- IP Control Port No.
- Firmware Update (Updating the internal firmware)
- Scene Link Manager (for devices other than XMV)
- Network Setup
- Synchronization (Synchronization with devices)
- Custom Control Panel Manager
- System View Creator
- Speaker Processor Library Converter
- Tree View window
- Detail View window
- Device Properties window
- Signal Path View window (TXn only)
- Component editor (TXn only)
- Custom control panels
- Appendix
Chapter 5 Main panel window
Amp Editor Owner’s Manual
73
When is selected
When the input voltage to GPI IN changes from below the center voltage to above it, the [Min]
value and [Max] value will be alternately specified.
Example: How the input voltage is related to the Attenuation when “Attenuation” is specified as the
parameter
When is selected
When the input voltage to GPI IN changes from above the center voltage to below it, the [Min]
value and [Max] value will be alternately specified.
Example: How the input voltage is related to the Attenuation when “Attenuation” is specified as the
parameter
[Direct Parameter Value]
The parameter of the component will be changed to a specific value. Use [Device] to select the ampli-
fier that will be controlled.
Use [Parameter] to specify the name of the parameter that will be edited. Use [Max] to specify the
edited value of the parameter. [Min] and [Trigger Type] are unavailable.
When the input voltage to GPI IN changes from below the center voltage to above it, the parameter
value will be set to the [Max] setting.
[Emergency Scene Recall]
Of the amplifiers connected to the device, the scene will be recalled to only the amplifier that specified
by the scene number in the EMG Scene Setup of the Utility dialog box.
[Device], [Parameter], [Min] and [Max] are unavailable. Use [Trigger Type] to specify how the input
voltage from GPI IN will be applied to the parameter.
GPI IN input voltage
max
GPI IN input voltage
min
[Max] value
Center
voltage
[Min] value [Max] value
GPI IN input voltage
max
GPI IN input voltage
min
[Min] value
Center
voltage
[Max] value [Min] value