POWER AMPLIFIER Owner’s Manual E
• Explanation of Graphical Symbols The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Precautions — For safe operation — WARNING ● Installation ● ● ● ● ● Connect this unit’s power cord only to an AC outlet of the type stated in this Owner’s Manual or as marked on the unit. Failure to do so is a fire and electrical shock hazard. Do not allow water to enter this unit or allow the unit to become wet. Fire or electrical shock may result. Do not place a container with liquid or small metal objects on top of this unit.
— For correct operation — Connector pin assignments ● XLR-type connectors are wired as follows Pin 1: ground; Pin 2: hot (+); Pin 3: cold (–). Interference from Cell Phones ● Use of a mobile phone near this unit may induce noise. If noise occurs, move the phone further from the unit. Always turn the power off when the amplifier is not in use. Illustrations in this manual are for explanatory purposes only, and may not match the actual appearance of the product during operation.
Introduction Thank you for your purchase of the YAMAHA P7000S, P5000S, P3500S or P2500S power amplifier. These P-series amplifiers fully incorporate Yamaha’s renown technological expertise, and offer high reliability, rock-solid stability, and superb acoustic characteristics—all in a trim, 2U-sized package.
Controls and Functions ■ Front Panel 2 8 1 4 3 57 6 1 POWER switch and indicator 8 How to install the security cover (1) Use the supplied hex wrench to remove the four attachment screws from the amplifier. (2) Adjust the security cover to the position of screw holes. Fasten it into place using the same screws. Press to toggle the power on or off. The POWER indicator lights up green when the power is ON. 2 TEMP indicator Lights up red if the heat sink temperature exceeds 85°C (185°F).
■ Rear Panel 12 SUB LOW CUT WOOFER OFF 5 SUB OFF WOOFER LOW CUT LOCK LOCK 3 90 ON OFF 50 Hz SPEAKERS 2 3 50 125 25 2 90 150 125 STEREO BRIDGE PARALLEL FREQUENCY 25 Hz 150 FREQUENCY INPUT 1+ 12+ 2- + 1+ - 1- - 1 + + (-) 1 + + - - (+) BRIDGE 43 1 FILTER switch and FREQUENCY adjustment knob (One pair for each channel) Use these controls to select the filter type and adjust the cutoff frequency on each channel (A and B).
4 STEREO/PARALLEL/BRIDGE switch Use this switch to select the operating mode. • STEREO mode Channels A and B operate independently (as with a conventional stereo amplifier). The Channel A input goes to the Channel A output jacks, and the Channel B input goes to the Channel B output jacks. • PARALLEL mode The Channel A input signal is output through both the Channel A and Channel B output jacks. The Channel B input jacks do not function. Channel A and B volumes can be independently adjusted.
Speaker Connections ■ Speaker impedance Speakers can be connected to the amplifier as shown below. Note that speaker impedance will vary according to the connection method and the number of speakers. Please be sure that your speakers’ impedance is not less than the relevant minimum value indicated below.
■ Wiring 5-way binding post Speakon connector (1) Turn off the POWER switch. (2) Remove the cover attachment screws and remove the protective cover from the speaker terminals. (1) Turn off the POWER switch. (2) Insert the Neutrik NL4FC plugs into the Speakon connector on the rear of the amplifier, and turn clockwise to lock.
Rack Mounting Mounting in a standard EIA rack If you are mounting multiple power amplifiers in a rack, be sure to install ventilation panel(s) as shown below. Also be sure to use metal brackets (one on each side) to support the rear of each amplifer. Note: EIA stands for Electronic Industries Alliance. Ventilation panel(s) Use 1U-size blank panel(s). 44 480 Unit: mm If mounting up to four amplifiers in an open-backed rack Install a ventilation panel as shown below.
Specifications ■ General Specifications Power Output Level (Rated Power) 1 kHz THD + N = 1% 8 Ω/STEREO 20 Hz – 20 kHz THD + N = 0.1% 1 kHz 20 ms non-clip Power Bandwidth Total Harmonic Distortion (THD + N) 20 Hz – 20 kHz, Half Power Frequency Response Intermodulation Distortion (IMD) 60 Hz:7 kHz, 4:1, Half Power Channel Separation Vol. max Residual Noise Vol. min.
■ Block Diagram P7000S, P5000S P3500S, P2500S HPF LPF BA State variable Active filter CHANNEL A ATT Ach Power Amp SPEAKERS Limiter 3 OFF Frequency [25 Hz-150 Hz] CHANNEL A [BRIDGE] [PARALLEL] 1+ SIGNAL YAMAHA SPEAKER PROCESSING 2- 2 Temperature Sensor (Heat Sink) ON OFF Protection Circuit 1 PROTECTION A+B BRIDGE TEMP YAMAHA SPEAKER PROCESSING 1 2+ CLIP SIGNAL CHANNEL B 2 12- BA State variable Active filter CHANNEL A 2+ INV INPUT 1- CLIP CHANNEL B ATT OFF PARALLEL BRIDGE S
■ Dimensions Unit: mm ■ Current Draw P7000S Line Current (A) 100/120V Power (W) 230/240V In Out Thermal Dissipation Dissipated Btu/h kcal/h standby 0.08 0.04 5 0 5 17 4 idle 1.0 0.5 35 0 35 119 30 1/8 power 1/3 power 8Ω/ch 5.4 3.0 379 188 191 653 165 4Ω/ch 8.5 4.7 611 275 336 1150 289 8Ω/ch 12.8 7.0 918 500 418 1430 360 4Ω/ch 20.6 11.
P2500S Line Current (A) 100/120V Power (W) 230/240V In Out Thermal Dissipation Dissipated Btu/h kcal/h standby 0.08 0.04 5 0 5 17 4 idle 1.0 0.5 25 0 25 85 22 8Ω/ch 2.4 1.3 174 69 105 358 90 4Ω/ch 3.6 2.0 271 98 173 592 149 8Ω/ch 5.6 3.1 421 183 238 811 204 4Ω/ch 8.8 4.8 657 260 397 1350 341 1/8 power 1/3 power 1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante. NORTH AMERICA CANADA Yamaha Canada Music Ltd. 135 Milner Avenue, Toronto, Ontario, M1S 3R1, Canada Tel: 416-298-1311 U.S.A. Yamaha Corporation of America 6600 Orangethorpe Avenue, Buena Park, CA 90620, U.S.A.