User Manual

MOX6/MOX8 Data List
110
MIDI Data Table
TOTAL SIZE = 80 50 (HEX)
TOTAL SIZE = 14 0E (HEX)
TOTAL SIZE = 38 26 (HEX)
Address Size Data Range
(HEX)
Parameter Name Settings Default
(HEX)
Notes
High Mid Low
30 00 00 1 00, 20 – 7E Performance Name 1 32..126 (ASCII) I
01 1 00, 20 – 7E Performance Name 2 32..126 (ASCII) n
02 1 00, 20 – 7E Performance Name 3 32..126 (ASCII) i
03 1 00, 20 – 7E Performance Name 4 32..126 (ASCII) t
04 1 00, 20 – 7E Performance Name 5 32..126 (ASCII) i
05 1 00, 20 – 7E Performance Name 6 32..126 (ASCII) a
06 1 00, 20 – 7E Performance Name 7 32..126 (ASCII) l
07 1 00, 20 – 7E Performance Name 8 32..126 (ASCII) i
08 1 00, 20 – 7E Performance Name 9 32..126 (ASCII) z
09 1 00, 20 – 7E Performance Name 10 32..126 (ASCII) e
0A 1 00, 20 – 7E Performance Name 11 32..126 (ASCII) d
0B 1 00, 20 – 7E Performance Name 12 32..126 (ASCII) P
0C 1 00, 20 – 7E Performance Name 13 32..126 (ASCII) e
0D 1 00, 20 – 7E Performance Name 14 32..126 (ASCII) r
0E 1 00, 20 – 7E Performance Name 15 32..126 (ASCII) f
0F 1 00, 20 – 7E Performance Name 16 32..126 (ASCII) o
10 1 00, 20 – 7E Performance Name 17 32..126 (ASCII) r
11 1 00, 20 – 7E Performance Name 18 32..126 (ASCII) m
12 1 00, 20 – 7E Performance Name 19 32..126 (ASCII)
13 1 00, 20 – 7E Performance Name 20 32..126 (ASCII)
14 1 reserved
15 1 reserved
16 1 reserved
17 1 reserved
18 1 00 – 07 Performance Category
(Main)
0..7 07
(NoAsg)
19 1 00 – 0B Performance Category
(Sub)
0..11 00 (--)
1A 1 reserved
1B 1 reserved
1C 1 reserved
1D 1 reserved
30 00 1E 1 00 – 22 Knob Function Select bit0-3 KnobUp:
0=Tone1, 1=Tone2,
2=Tone3
bit4-7 KnobLo: 0=EQ,
1=Fx, 2=Arp
00
1F 1 01 – 7F Pan L63..C..R63 40
20 1 reserved
21 1 00 – 7F AEG Attack Time -64..+63 40
22 1 00 – 7F AEG Decay Time -64..+63 40
23 1 00 – 7F AEG Sustain Level -64..+63 40
24 1 00 – 7F AEG Release Time -64..+63 40
25 1 00 – 7F FEG Attack Time -64..+63 40
26 1 00 – 7F FEG Decay Time -64..+63 40
27 1 reserved
28 1 00 – 7F FEG Release Time -64..+63 40
29 1 00 – 7F FEG Depth -64..+63 40
2A 1 00 – 7F Cutoff Frequency -64..+63 40
2B 1 00 – 7F Resonance -64..+63 40
2C 1 reserved
2D 1 reserved
2E 1 00 – 7F EQ Low Frequency -64..+63 40
2F 1 00 – 7F EQ Low Gain -64..+63 40
30 1 reserved
31 1 00 – 7F EQ Mid Frequency -64..+63 40
32 1 00 – 7F EQ Mid Gain -64..+63 40
33 1 00 – 7F EQ Mid Q -64..+63 40
34 1 reserved
35 1 00 – 7F EQ High Frequency -64..+63 40
36 1 00 – 7F EQ High Gain -64..+63 40
37 1 reserved
38 1 00 – 7F Volume 0..127 7F
39 1 00 – 7F Portamento Time -64..+63 40
3A 1 00 – 01 Portamento Switch off, on 01
3B 1 00 – 7F Reverb Send 0..127 7F
3C 1 00 – 7F Chorus Send 0..127 7F
30 00 3D 1 reserved
3E 1 reserved
3F 1 00 – 01 Assignable Switch 1 Mode momentary, latch 01
40 1 00 – 01 Assignable Switch 2 Mode momentary, latch 01
41 1 reserved
42 1 01 – 7F Split Point C#-2...G8 3C
43 1 00 – 01 Split Switch off, on 00
44 1 reserved
45 1 reserved
46 1 reserved
47 1 reserved
48 1 reserved
49 1 reserved
4A 1 reserved
4B 1 01 – 02 A/D Input Insertion
Connect Type
ins A>B, ins B>A 01
4C 4 00 – 00
00 – 20
00 – 00
00 – 0F
Insertion Part Sw 1st bit6-0: reserved
2nd bit6: reserved
2nd bit5: off, on A/D
Part
2nd bit4-0: reserved
3rd bit6-0: reserved
4th bit6-4: reserved
4th bit3: off, on Part 4
4th bit2: off, on Part 3
4th bit1: off, on Part 2
4th bit0: off, on Part 1
00
00
00
07
Up to three
parts can
be turned
on simulta-
neously.
Address Size Data Range
(HEX)
Parameter Name Settings Default
(HEX)
Notes
High Mid Low
30 30 00 1 00 – 05 ARP SF Select SF1 ~ SF6 00
01 1 reserved
02 2 00 – 02
05 – 2C
ARP Tempo 5..300 00 5A
04 1 00 – 01 ARP Common Switch off, on 00
05 1 00 – 07 ARP Sync Quantize Value off, 32th, 16th_Triplet,
16th, 8th_Triplet, 8th,
4th_Triplet, 4th
00
06 2 00 – 01
1C – 64
ARP Quantize Strength
Offset
-100 … +100 00 80
08 2 00 – 01
1C – 64
ARP Gate Time Rate
Offset
-100 … +100 01 00
0A 2 00 – 01
1C – 64
ARP Velocity Rate Offset -100 … +100 01 00
0C 2 00 – 01
08 – 78
ARP Swing Offset -120 … +120 01 00
Address Size Data Range
(HEX)
Parameter Name Settings Default
(HEX)
Notes
High Mid Low
30 01 00 2 00 – 7F
00 – 7F
Reverb Type Refer to the “Effect
Type List.”
01 00 Rev-X Hall
02 1 00 – 7F Preset Number 00 Basic
03 1 reserved
04 2 00 – 7F
00 – 7F
Reverb Parameter 1 Refer to the “Effect
Parameter List.”
Init value for Rev-X
Hall / Basic
06 2 00 – 7F
00 – 7F
Reverb Parameter 2 : Init value for Rev-X
Hall / Basic
08 2 00 – 7F
00 – 7F
Reverb Parameter 3 : Init value for Rev-X
Hall / Basic
0A 2 00 – 7F
00 – 7F
Reverb Parameter 4 : Init value for Rev-X
Hall / Basic
0C 2 00 – 7F
00 – 7F
Reverb Parameter 5 : Init value for Rev-X
Hall / Basic
0E 2 00 – 7F
00 – 7F
Reverb Parameter 6 : Init value for Rev-X
Hall / Basic
10 2 00 – 7F
00 – 7F
Reverb Parameter 7 : Init value for Rev-X
Hall / Basic
12 2 00 – 7F
00 – 7F
Reverb Parameter 8 : Init value for Rev-X
Hall / Basic
14 2 00 – 7F
00 – 7F
Reverb Parameter 9 : Init value for Rev-X
Hall / Basic
16 2 00 – 7F
00 – 7F
Reverb Parameter 10 : Init value for Rev-X
Hall / Basic
18 2 00 – 7F
00 – 7F
Reverb Parameter 11 : Init value for Rev-X
Hall / Basic
1A 2 00 – 7F
00 – 7F
Reverb Parameter 12 : Init value for Rev-X
Hall / Basic
1C 2 00 – 7F
00 – 7F
Reverb Parameter 13 : Init value for Rev-X
Hall / Basic
1E 2 00 – 7F
00 – 7F
Reverb Parameter 14 : Init value for Rev-X
Hall / Basic
20 2 00 – 7F
00 – 7F
Reverb Parameter 15 : Init value for Rev-X
Hall / Basic
22 2 00 – 7F
00 – 7F
Reverb Parameter 16 : Init value for Rev-X
Hall / Basic
24 1 00 – 7F Reverb Return -∞dB…0dB…+6dB
(0…96…127)
40
25 1 01 – 7F Reverb Pan L63…C…R63 40
Address Size Data Range
(HEX)
Parameter Name Settings Default
(HEX)
Notes
High Mid Low
30 02 00 2 00 – 7F
00 – 7F
Chorus Type Refer to the “Effect
Type List.”
03
00
G Chorus
02 1 00 – 7F Preset Number 00 Basic
03 1 reserved
04 2 00 – 7F
00 – 7F
Chorus Parameter 1 Refer to the “Effect
Parameter List.”
Init value for G
Chorus / Basic
06 2 00 – 7F
00 – 7F
Chorus Parameter 2 : Init value for G
Chorus / Basic
08 2 00 – 7F
00 – 7F
Chorus Parameter 3 : Init value for G
Chorus / Basic
Address Size Data Range
(HEX)
Parameter Name Settings Default
(HEX)
Notes
High Mid Low
MIDI PARAMETER CHANGE TABLE
(PERFORMANCE COMMON)