Data List

MODX Data List
185
MIDI Data Format
PORTAMENTO TIME sets the time it takes for the pitch to reach the next note played when PORTAMENTO
SWITCH is set to on.
PAN position relatively changes according to the preset value for each Part.
EFFECTS 1 DEPTH controls Reverb Send Level.
EFFECTS 4 DEPTH controls Variation Send Level.
HARMONIC CONTENT adjusts the Resonance preset for each Part.
Setting a value adds to or subtracts from the center value, 64, since it is an offset parameter.
The larger the value more resonant sound will be produced.
The effective range may be narrower than the range you can designate depending on the selected Part.
The parameters, EG ATTACK TIME, EG DECAY TIME, EG SUSTAIN LEVEL, EG RELEASE TIME adjust the
envelopes preset for each Part.
Setting these values add to or subtract from the center value, 64, since these are offset parameters.
BRIGHTNESS adjusts the Cutoff Frequency preset for each Part.
Setting a value adds to or subtracts from the center value, 64, since it is an offset parameter.
The smaller the value the Cutoff Frequency will be lowered.
The effective range may be narrower than the range you can designate depending on the selected voice.
Bank Select will be actually executed when the Program Change message is received.
Bank Select and Program Change numbers that are not supported by Yamaha will be ignored.
(3-1-4) PROGRAM CHANGE
STATUS 1100nnnn (CnH) n = 0 - 15 CHANNEL NUMBER
PROGRAM NUMBER 0ppppppp p = 0 - 127
(3-1-5) CHANNEL AFTER TOUCH
STATUS 1101nnnn (DnH) n = 0 - 15 CHANNEL NUMBER
VALUE 0vvvvvvv v = 0 - 127 AFTER TOUCH VALUE
Receive only
(3-1-6) PITCH BEND CHANGE
STATUS 1110nnnn (EnH) n = 0 - 15 CHANNEL NUMBER
LSB 0vvvvvvv PITCH BEND CHANGE LSB
MSB 0vvvvvvv PITCH BEND CHANGE MSB
Transmitted with a resolution of 7 bits.
(3-2) CHANNEL MODE MESSAGES
STATUS 1011nnnn (BnH) n = 0 - 15 CHANNEL NUMBER
CONTROL NUMBER 0ccccccc c = CONTROL NUMBER
CONTROL VALUE 0vvvvvvv v = DATA VALUE
(3-2-1) ALL SOUND OFF (CONTROL NUMBER = 78H, DATA VALUE = 0)
All the sounds currently played including the Channel Messages such as Note-On and Hold-On in a certain
channel are muted when receiving this message.
(3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H, DATA VALUE = 0)
Resets the values set for the following controllers.
PITCH BEND CHANGE 0 (center)
CHANNEL AFTER TOUCH 0 (minimum)
MODULATION 0 (minimum)
EXPRESSION 127 (maximum)
BREATH CONTROLLER 127 (maximum)
FOOT CONTROLLER 1 127 (maximum)
FOOT CONTROLLER 2 127 (maximum)
FOOT SWITCH 0 (off)
RIBBON CONTROLLER 0 (center)
ASSIGNABLE FUNCTION 1 0 (off)
ASSIGNABLE FUNCTION 2 0 (off)
MOTION SEQ HOLD 0 (off)
SUSTAIN SWITCH 0 (off)
SOSTENUTO SWITCH 0 (off)
MOTION SEQ LANE 1 0 (
minimum when Polarity is set to Unipolar and center when Polarity is set to Bipolar
)
MOTION SEQ LANE 2 0 (
minimum when Polarity is set to Unipolar and center when Polarity is set to Bipolar
)
MOTION SEQ LANE 3 0 (
minimum when Polarity is set to Unipolar and center when Polarity is set to Bipolar
)
MOTION SEQ LANE 4 0 (
minimum when Polarity is set to Unipolar and center when Polarity is set to Bipolar
)
RPN Not assigned; No change
Doesn’t reset the following data:
PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN, HARMONIC CONTENT, SUSTAIN LEVEL,
RELEASE TIME, ATTACK TIME, DECAY TIME, BRIGHTNESS, EFFECTS 1 DEPTH, EFFECTS 4
DEPTH,PORTAMENTO SWITCH, PITCH BEND SENSITIVITY, FINE TUNING, COARSE TUNING,
ASSIGNABLE KNOB 1-8
(3-2-3) ALL NOTE OFF (CONTROL NUMBER = 7BH, DATA VALUE = 0)
All the notes currently set to on in certain channel(s) are muted when receiving this message.
However, if Sustain or Sostenuto is on, notes will continue sounding until these are turned off.
(3-2-4) OMNI MODE OFF (CONTROL NUMBER = 7CH, DATA VALUE = 0)
Performs the same function as when receiving ALL NOTES OFF.
(3-2-5) OMNI MODE ON (CONTROL NUMBER = 7DH, DATA VALUE = 0)
Performs the same function as when receiving ALL NOTES OFF.
(3-2-6) MONO (CONTROL NUMBER = 7EH, DATA VALUE = 0..16)
Performs the same function as when receiving ALL SOUNDS OFF.
If the 3rd byte (mono) is within 0 through 16, the channel will be Mode 4 (m = 1).
(3-2-7) POLY (CONTROL NUMBER = 7FH, DATA VALUE = 0)
Performs the same function as when receiving ALL SOUNDS OFF. The channel will be Mode 3.
(3-3) REGISTERED PARAMETER NUMBER
STATUS 1011nnnn (BnH) n = 0 - 15 CHANNEL NUMBER
LSB 01100100 (64H)
RPN LSB 0ppppppp p = RPN LSB
(Refer to the table as shown below.)
MSB 01100101 (65H)
RPN MSB 0qqqqqqq q = RPN MSB
(Refer to the table as shown below.)
DATA ENTRY MSB 00000110 (06H)
DATA VALUE 0mmmmmmm m = Data Value
DATA ENTRY LSB 00100110 (26H)
DATA VALUE 0lllllll l = Data Value
First, designate the parameter using RPN MSB/LSB numbers. Then, set its value with data entry MSB/LSB.
RPN D.ENTRY
LSB MSB MSB LSB PARAMETER NAME DATA RANGE
00H 00H mmH --- PITCH BEND SENSITIVITY 00H - 18H (0 - 24 semitones)
01H 00H mmH llH MASTER FINE TUNE {mmH,llH}={00H,00H}-{40H,00H}-{7FH,7FH}
(-8192*100/8192) - 0 - (+8191*100/8192)
02H 00H mmH --- MASTER COARSE TUNE 28H - 40H - 58H (-24 - 0 - +24 semitones)
7FH 7FH --- --- RPN RESET
RPN numbers will be left not designated.
The internal values are not affected.
(3-4) SYSTEM REAL TIME MESSAGES
(3-4-1) ACTIVE SENSING
STATUS 11111110 (FEH)
Transmitted at every 200 msec.
Once this code is received, the instrument starts sensing.
When no status nor data is received for over approximately 350 ms, MIDI receiving buffer will be cleared, and
the sounds currently played is forcibly turned off.
(3-5) SYSTEM EXCLUSIVE MESSAGE
(3-5-1) UNIVERSAL NON REALTIME MESSAGE
(3-5-1-1) GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The internal tone generator block will receive this message except when the Compare function is activated.
(3-5-1-2) IDENTITY REQUEST (Receive only)
F0H 7EH 0nH 06H 01H F7H
(“n” = Device No. However, this instrument receives under “omni.”)
(3-5-1-3) IDENTITY REPLY (Transmit only)
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH mmH 00H 00H 7FH F7H
dd: Device family number/code
MODX6: 56H 06H
MODX7: 57H 06H
MODX8: 58H 06H
mm: version
mm = (version no. - 1.0) * 10
e.g.) version 1.0 mm = (1.0 - 1.0) * 10 = 0
version 1.5 mm = (1.5 - 1.0) * 10 = 5
(3-5-2) UNIVERSAL REALTIME MESSAGE
(3-5-2-1) MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
Sets the MASTER VOLUME value.
The value “mm” is used to set the master volume (the value “ll” should be ignored).
(3-5-3) PARAMETER CHANGE
(3-5-3-1) NATIVE PARAMETER CHANGE, MODE CHANGE
11110000 F0 Exclusive Status
01000011 43 YAMAHA ID
0001nnnn 1n Device Number
01111111 7F Group ID High
00011100 1C Group ID Low
00000010 07 Model ID
0aaaaaaa aaaaaaa Address High
0aaaaaaa aaaaaaa Address Mid
0aaaaaaa aaaaaaa Address Low
0ddddddd ddddddd Data
||
11110111 F7 End of Exclusive
For parameters with data size of 2 or more, the appropriate number of data bytes will be transmitted.
See the following MIDI Data Table for Address.
(3-5-4) BULK DUMP
11110000 F0 Exclusive Status
01000011 43 YAMAHA ID
0000nnnn 0n Device Number
01111111 7F Group ID High
00011100 1C Group ID Low
0bbbbbbb bbbbbbb Byte Count
0bbbbbbb bbbbbbb Byte Count
00000010 07 Model ID
0aaaaaaa aaaaaaa Address High
0aaaaaaa aaaaaaa Address Mid
0aaaaaaa aaaaaaa Address Low
0 0 Data
||
0ccccccc ccccccc Check-sum
11110111 F7 End of Exclusive
See the following BULK DUMP Table for Address and Byte Count.
The Check sum is the value that results in a value of 0 for the lower 7 bits when the Byte Count, Start Address,
Data and Check sum itself are added.
(3-5-5) DUMP REQUEST
11110000 F0 Exclusive Status
01000011 43 YAMAHA ID
0010nnnn 2n Device Number
01111111 7F Group ID High
00011100 1C Group ID Low
00000010 07 Model ID
0aaaaaaa aaaaaaa Address High
0aaaaaaa aaaaaaa Address Mid
0aaaaaaa aaaaaaa Address Low
11110111 F7 End of Exclusive
See the following DUMP REQUEST Table for Address.
(3-5-6) PARAMETER REQUEST
11110000 F0 Exclusive Status
01000011 43 YAMAHA ID
0011nnnn 3n Device Number
01111111 7F Group ID High
00011100 1C Group ID Low
00000010 07 Model ID
0aaaaaaa aaaaaaa Address High
0aaaaaaa aaaaaaa Address Mid
0aaaaaaa aaaaaaa Address Low
11110111 F7 End of Exclusive
See the following MIDI Data Table for Address.