Super Knob CC (Super Knob Control Change Number)
Determines the Control Change number generated by using the Super Knob. Even when the instrument
receives MIDI messages with the same Control Change Number specified here from the external
equipment, the instrument assumes that the message is generated by using the Super Knob. When “MIDI
I/O Mode” is set to “Multi,” Channel 1 is used for transmitting MIDI data. When “MIDI I/O Mode” is set to
“Single,” the channel specified in “MIDI I/O Ch.” is used for transmitting MIDI data.
Settings: Off, 1–95
NOTE When this parameter is set to off, MIDI data is transmitted by SysEx (System Exclusive) messages.
Scene CC (Scene Control Change Number)
Determines the Control Change Number generated by switching Scenes. Even when the instrument
receives MIDI message with the same Control Change Number specified here from the external
equipment, the instrument assumes that the message is generated by switching Scenes.
Settings: Off, 1–95
NOTE Scene 1–8 is selected depending on the Control Change value.
0–15: Scene 1, 16–31: Scene 2, 32–47: Scene 3, 48–63: Scene 4, 64–79: Scene 5, 80–95: Scene 6, 96–111:
Scene 7, 112–127: Scene 8
NOTE When the same Control Change Number is set to both of the Super Knob Control Change and the Scene Control
Change, an exclamation mark (!) is shown before the value. In such a case, changes to Scene Control have
priority and changes to the Super Knob Control are ignored.
Control Number
Calls up the Control Number display in the Common/Audio Edit.
From the Advanced display you can set the advanced parameters. Data communication between this
instrument and an external device using only the specified MIDI channel is also available.
Zone Master (Zone Master Switch)
Determines whether the Zone function is used (on) or not (off).
Settings: Off, On
Audition Lock
Determines whether the Audition Lock is active or not. When this is set to On, the Audition function is not
available.
Settings: Off, On