Trouble Recovery
74
ther information, see page 36. Be sure
the engine is in neutral and that the en-
gine stop switch lanyard lock plate is at-
tached to the engine stop switch.
4. Turn on the main switch.
5. Insert the knotted end of the emergency
starter rope into the notch in the flywheel
rotor and wind the rope around the fly-
wheel several turns clockwise.
6. Give a strong pull straight out to crank
the engine. Repeat if necessary.
WARNING
EWM00620
Do not install the top cowling when en-
gine is running.
EMU29670
Engine fails to operate
EMU29741
Low oil level warning activates
If the oil level is allowed to drop too low, the
red segment will appear on the oil level indi-
cator, the buzzer will sound, and engine
speed will be limited to about 2000 r/min. If
this happens, a reserve amount of oil can be
pumped from the remote oil tank to the en-
gine oil tank using the emergency switch.
WARNING
EWM01050
Be sure to stop the engine before per-
forming this procedure.
CAUTION:
ECM00900
If the emergency switch is held up too
long, too much oil will be pumped into
the engine oil tank, overflowing it. Re-
lease the switch when oil reaches the
upper level line on the engine oil tank.
Do not use this emergency procedure
unless the oil level warning indicators
are working.
ZMU02334
ON
START
OFF
ON
START
OFF
ZMU04589
ON STARTOFF
ZMU01906
ZMU04444