User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Warning/Error Messages
- Index
- Data List
- Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
Setup
Reference Manual
227
REMOTE HA settings
Here’s how to select which of the multiple HA devices on the Dante audio network will be
mounted so that they can be used. Up to 8 units can be mounted for one QL series console.
DANTE SETUP window (REMOTE HA page)
1 CLEAR ALL button
Clears all HA devices in the list to an unmounted state.
2 REFRESH button
Updates the displayed list of HA devices on the Dante audio network.
3 HA device select buttons
Press one of these buttons to open the REMOTE HA SELECT window. The upper line of
the button shows the device label. The lower line of the button shows the model name
and the number of inputs and outputs. If no device has been mounted, the upper row
will indicate “---” and the lower row will show nothing.
For more information on VIRTUAL/CONFLICT/DUPLICATE shown below these buttons,
refer to
1 on page 149, “I/O device list.”
REMOTE HA SELECT window
1 DEVICE LIST
Shows a list of the HA devices on the Dante audio network.
2 WITH RECALL button
If this button is on, the settings saved in the QL series console will be applied to the HA
device when the QL series console starts up and when a scene is recalled.
3 DEVICE LIST select knob
Use the [TOUCH AND TURN] knob to select the HA device that you want to mount.
NOTE
• Do not specify “WITH RECALL” if an HA device is shared by multiple QL series consoles and
settings have already been made on a different QL series console.
• The HA device can also be operated from a QL series console that is not set to “WITH RECALL.”
• If an external QL series console has been mounted, you can set up and control the QL series
console’s INPUT HA in this window. However, make sure that the UNIT ID of the QL series
console does not match the UNIT IDs of any other HA device.
STEP
1. Press the REMOTE HA ASSIGN tab in the lower part of the DANTE SETUP window.
2. Press a HA device select button to access the REMOTE HA SELECT window.
3. Select the HA device to mount and press the OK button.
If you have changed the setting by pressing the WITH RECALL button, a
confirmation dialog box will appear. Press the OK button.
13 2
1
3
2