AV Receiver Owner's Manual
29
AUTO SETUP
PREPARATION
■
Troubleshooting for auto setup procedure
Before auto setup
During auto setup
Press l / h to display the detailed information about individual errors. Select “RETRY” to try auto setup procedure
again.
Error message Cause Remedy
Connect MIC!
Optimizer microphone is not connected. • Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
Unplug HP!
Headphones are connected. • Unplug the headphones.
Error message Cause Remedy
E-1:NO FRONT SP
Front L/R channel signal(s) is (are) not
detected.
• Select the front speakers with SPEAKER A or B.
• Check the front L/R speaker connections.
E-2:NO SURR.SP
A surround channel signal is not detected. • Check the surround speaker connections.
E-3:NO PRES. SP
A presence channel signal is not detected. • Check the presence speaker connections.
E-4:SBR->SBL
Only right surround back channel signal is
detected.
• Connect the surround back speaker to the LEFT
SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.
E-5:NOISY
Background noise is too loud. • Try auto setup procedure in a quiet environment.
• Turn off noisy electric equipment like air conditioners
(etc.) or move them away from the optimizer
microphone.
E-6:CHECK SURR.
Surround back speaker(s) is (are) connected,
though surround L/R speakers are not.
• Connect surround speakers when you use (a)
surround back speaker(s).
E-7:NO MIC
The optimizer microphone was unplugged
during the auto setup procedure.
• Connect the supplied optimizer microphone to
OPTIMIZER MIC jack on the front panel.
E-8:NO SIGNAL
The optimizer microphone does not detect test
tones.
• Check the microphone setting.
• Check the speaker connections and placement.
E-9:USER CANCEL
The auto setup procedure was cancelled due to
user activity.
• Perform the auto setup procedure again.
E-10:OTHER ERROR
An internal error occurred. • Perform the auto setup procedure again.
01EN00_HTR5890U.book Page 29 Thursday, December 23, 2004 12:39 PM