Making adjustments
Adjusting the stylus pressure
Adjustthetonearmsothattheappropriatestyluspressure
will be applied to the record.
1
Remove the tonearm from the arm
rest and move it slightly towards the
record.
NOTICE
Takecarethatthestylusdoesnotcontactany
part of the unit.
2
Turn the counter weight so that the
tonearm will be horizontal.
1
2
Toward
1
: Counter weight moves forward
on the tonearm.
Toward
2
: Counter weight moves backward
on the tonearm.
3
Return the tonearm to the arm rest.
4
Turn the VTF dial so that the “0”
marking will be aligned with the center
line on the back end of the tonearm.
Center line
Note
WhenturningtheVTFdial,useyourngersto
hold the counter weight in place so that it will not
rotate.
5
Turn the counter weight to set the VTF
dial markings to the stylus pressure
specied for the cartridge.
Note
• TurningthecounterweightalsoturnstheVTF
dial.
• Use a stylus pressure gauge to set an accurate
stylus pressure.