User Guide

8-45
SIGNAL SYSTEM
ELEC
1 2
1
1.Bulb and bulb socket
Check the bulb and bulb socket for continu-
ity.
Replace the bulb and/or bulb socket.
CONTINUITY
NO CONTINUITY
3.Diode
Remove the diode from the wire harness.
Check for continuity as follows:
Sky blue – Light green
Replace the diode.
CORRECT
INCORRECT
2.Neutral switch
Disconnect the neutral switch lead from the
neutral switch.
Check for continuity as follows:
Neutral switch terminal – Ground
Replace the neutral switch.
CONTINUITY
NO CONTINUITY
Tester (+) lead Sky blue
Tester (–) lead Light green
1
Tester (+) lead Light green
Tester (–) lead Sky blue
Continuity
No
Continuity
2
1
2
EB806024