Owner's Manual

DSP-R10 Owner’s Manual
9
Front Panel
1 LCD
Indicates the setting parameters for the unit.
2 Color Indicator
Indicates the status of the unit.
3 [MENU] key
The following setting parameters are indicated on the
LCD:
4 [ENTER] key
Confirms the setting parameter or the value.
5 [U]/[D] keys
Enable you to select a setting parameter or value.
6 MY card slots
Enable you to install optional Mini-YGDAI cards.
7 [I]/[P] (Power switches)
Toggle between power on (I) and off (P). When the
power unit is turned on, the indicator lights up.
Caution
Rapidly turning the unit on and off in succession can
cause it to malfunction. After turning the unit off, wait for
at least 6 seconds before turning it on again.
Even when the power switch is turned off, a small
amount of current is flowing through the unit. If you plan
not to use the unit for a long period of time, remove the
power cord from the AC outlet.
NOTE
To maintain power supply redundancy, turn both power
supply units A and B ON or OFF together. If only one
power supply unit is ON, the LCD will display an error
message and the color indicator will light up yellow.
Part Names & Functions
3 765
21
4
Red
(flashing)
A critical error has occurred.
Yellow
(lit steadily)
Indicates a minor issue, but you can
continue using the unit.
Green Normal
Unit ID Specifies the Unit ID for the unit. You must set
a unique ID for each device connected to the
same I/O network so that they will be
identified correctly.
For more information on setting the Unit ID,
refer to “Setting the Unit ID” in the RIVAGE
PM10 System Setup Guide.
Fan Spd Specifies the speed of the cooling fans on the
unit.
This setting does not affect the speed of the
cooling fans on the power supply units.
Brightns Adjusts the brightness of the LCD.
Contrast Sets the contrast of the LCD screen.
FaultOut Specifies the conditions under which an alert
for abnormality is transmitted from the FAULT
OUTPUT connector.
Red: An alert is transmitted if an error occurs
that causes the color indicator to flash red.
Y&R: An alert is transmitted if an error occurs
that causes the color indicator to light up
yellow steadily or flash red.
F/W Ver. Indicates the current firmware version
number of the unit.
Initialz Initializes the unit.