Replacing the DME64N/24N startup screen
The screen image appearing when the DME64N/24N starts up can be replaced with a graphic file of
your choice in the following way. This function allows you to display a desired startup screen-for
example, one that includes your facility's name and logo.
Preparing the graphic data
Create the desired graphic data at a size of 160 x 48 dots in black-and-white bitmap format
(extension .bmp) and save it as a file with the name “opening.bmp.”
Replacing the graphic data
Transmit the graphic file (“opening.bmp”) to the DME unit using the DME File Storage function from
the DME Designer. This image will be displayed at the startup screen from the next time when the
DME starts up.
NOTE
•To restore the default startup screen, create a dummy file and change the name to “blank.bmp. and storage it in the same
way as above. The default startup screen will be displayed from the next time when the DME starts up.
The file transmitted to the DME unit using the DME File Storage function will be automatically erased after completing the
internal configuration. This means the file is not stored on the DME unit.
Compatible graphic files are limited to black-and-white bitmap format at a size of 160 x 48. Other graphic files cannot be
displayed.
The “Copyright indication at the bottom of the screen cannot be erased.
Only the DME64N/24N is compatible with this function. The ICP1 is incompatible.